EasyPact TVS contactor 3 poles for motor applications up to 9A 4kW@440V. It provides a 220V 50Hz AC coil, 1NO built-in auxiliary contacts, power and control connections by screw clamp terminals. 45mm width for standard operating rates up to 1800 cycles per hour. It procures standard reliability and durability with 1.4 Mcycles electrical durability AC-3 and 10 Mcycles mechanical durability. It can cover -5°C to 55°C working temperature and mounted by DIN-rail, No derating up to 3000m altitude. Multi-standards certified (IEC, CCC, EAC) and Green Premium compliant (RoHs/Reach).
Main
Range: Easy TeSys
Range of product: Easy TeSys Control
Product or component type: Contactor
Device short name: LC1E
Contactor application: Motor control
Resistive load
Utilisation category: AC-3
AC-3e
AC-1
Poles description: 3P
[Ue] rated operational voltage: Power circuit: <= 690 V AC 50/60 Hz
[Ie] rated operational current: 9 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
9 A (at <55 °C) at <= 440 V AC AC-3e for power circuit
25 A (at <55 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage: 220 V AC 50 Hz
Motor power kW: 2.2 kW at 220/230 V AC 50/60 Hz
4 kW at 380/400 V AC 50/60 Hz
4 kW at 415/440 V AC 50/60 Hz
4 kW at 500 V AC 50/60 Hz
4 kW at 660/690 V AC 50/60 Hz
5.5 kW at 660…690 V AC 50/60 Hz
Pole contact composition: 3 NO
[Ith] conventional free air thermal current: 25 A (at 55 °C) for power circuit
Irms rated making capacity: 117 A at 440 V AC for power circuit conforming to IEC 60947-4-1
Rated breaking capacity: 76.5 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 105 A 40 °C – 10 s for power circuit
61 A 40 °C – 60 s for power circuit
30 A 40 °C – 600 s for power circuit
Associated fuse rating: 20 A gG at <= 690 V coordination type 1 for power circuit
10 A gG at <= 690 V for auxiliary contact circuit conforming to IEC 60947-5-1
Average impedance: 2.5 mOhm – Ith 25 A 50 Hz for power circuit
Power dissipation per pole: 0.2 W AC-3
1.6 W AC-1
[Ui] rated insulation voltage: 690 V conforming to IEC 60947-4-1
Overvoltage category: III
Pollution degree: 3
[Uimp] rated impulse withstand voltage: 6 kV coil not connected to the power circuit conforming to IEC 60947
Mechanical durability: 10000000 cycles
Electrical durability: 1400000 cycles AC-3
150000 cycles AC-1
Control circuit type: AC at 50 Hz
Control circuit voltage limits: 0.85…1.1 Uc (-5…55 °C):operational 50 Hz
0.3…0.6 Uc (-5…55 °C):drop-out 50 Hz
Inrush power in VA: 95 VA 50 Hz cos phi 0.75 (at 20 °C)
95 VA 60 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA: 8.3 VA 50 Hz cos phi 0.3 (at 20 °C)
8.5 VA 60 Hz cos phi 0.3 (at 20 °C)
Heat dissipation: 2…3 W for control circuit
Operating time: 12…22 ms on closing
4…19 ms on opening
Maximum operating rate: 1800 cyc/h 60 °C
Connections – terminals: Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid without cable end
Tightening torque: Power circuit: 1.2 N.m
Control circuit: 1.2 N.m
Auxiliary contact composition: 1 NO
Minimum switching voltage: 17 V for auxiliary contact circuit
Minimum switching current: 5 mA for auxiliary contact circuit
Insulation resistance: > 10 MOhm for auxiliary contact circuit
Non-overlap time: 1.5 ms on energisation guaranteed between NC and NO contact
1.5 ms on de-energisation guaranteed between NC and NO contact
Mounting support: Plate
DIN rail
Complementary
Standards: EN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
GB/T 14048.1
GB/T 14048.4
GB/T 14048.5
EN/IEC 60335-1:Clause 30.2
EN/IEC 60335-2-40:Annex JJ
IS/IEC 60947-1
IS/IEC 60947-4-1
IS/IEC 60947-5-1
Product certifications: CB Scheme
CCC
CE
EAC
BIS
IP degree of protection: IP2X conforming to IEC 60529
Protective treatment: TH (pollution degree 3) conforming to IEC 60068-2-30
Permissible ambient air temperature around the device: -20…70 °C at Uc
-60…80 °C storage
-5…55 °C operation
Operating altitude: 3000 m without derating
Fire resistance: 850 °C conforming to IEC 60695-2-1
Mechanical robustness: Vibrations contactor open (1.5 Gn, 5…300 Hz)
Vibrations contactor closed (3 Gn, 5…300 Hz)
Shocks contactor open (7 Gn for 11 ms)
Shocks contactor closed (10 Gn for 11 ms)
Height: 74 mm
Width: 45 mm
Depth: 80 mm
Net weight: 0.3 kg
Environment
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 8.700 cm
Package 1 Width: 5.000 cm
Package 1 Length: 7.500 cm
Package 1 Weight: 339.000 g
Unit Type of Package 2: S02
Number of Units in Package 2: 36
Package 2 Height: 15.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 12.932 kg
Unit Type of Package 3: P06
Number of Units in Package 3: 576
Package 3 Height: 75.000 cm
Package 3 Width: 60.000 cm
Package 3 Length: 80.000 cm
Package 3 Weight: 215.412 kg
Contractual warranty
Warranty (in months): 18