Description
High power contactor, TeSys Giga, 4 pole (4NO), AC-1 <=440V 305A, standard version, 100…250V wide band AC/DC coil
SKU: LC1G1854KUEN
Description: TeSys Giga high power contactor, 4 poles (4 NO) for category AC-1 applications up to 305A @440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 143mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
Specifications
Main
Range: TeSys
Range of product: TeSys Giga
Product or component type: Contactor
Device short name: LC1G
Contactor application: Power switching
Utilisation category: AC-3
AC-3e
AC-1
AC-5a
AC-5b
AC-6a
AC-6b
DC-1
DC-3
DC-5
Poles description: 4P
[Ue] rated operational voltage: <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current: 185 A (at <60 °C) at <= 440 V AC-3
305 A (at <40 °C) at <= 1000 V AC-1
[Uc] control circuit voltage: 100…250 V AC 50/60 Hz
100…250 V DC
Control circuit voltage limits: Operational: 0.8 Uc Min…1.1 Uc Max (at <60 °C)
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <60 °C)
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 305 A (at 40 °C)
Rated breaking capacity: 1610 A at 440 V
[Icw] rated short-time withstand current: 1.5 kA – 10 s
0.92 kA – 30 s
0.74 kA – 1 min
0.5 kA – 3 min
0.4 kA – 10 min
Associated fuse rating: 200 A aM at <= 440 V for motor
160 A aM at <= 690 V for motor
315 A gG at <= 690 V
300 A UL Type J at <= 600 V
Average impedance: 0.00017 Ohm
[Ui] rated insulation voltage: 1000 V
Power dissipation per pole: 20 W AC-1 – Ith 305 A
6 W AC-3 – Ith 185 A
Compatibility code: LC1G
Pole contact composition: 4 NO
Auxiliary contact composition: 1 NO + 1 NC
Irms rated making capacity: 2310 A at 440 V
Coil technology: Built-in bidirectional peak limiting
Safety reliability level: B10d = 400000 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 8 Mcycles
inrush power in VA (50/60 Hz, AC): 540 VA
inrush power in W (DC): 380 W
hold-in power consumption in VA (50/60 Hz, AC): 12.4 VA
hold-in power consumption in W (DC): 7.8 W
Operating time: 40…70 ms closing
15…50 ms opening
Maximum operating rate: 600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
Connections – terminals: Power circuit: bar 2 – busbar cross section: 25 x 6 mm
Power circuit: lugs-ring terminals 1 185 mm²
Control circuit: push-in 1 0.2…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 1 0.25…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: push-in 2 0.5…1.0 mm² with cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: solid stranded without cable end
Control circuit: push-in 0.75…2.5 mm² – cable stiffness: flexible with cable end
Connection pitch: 35 mm
Mounting support: Plate
Standards: EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
UL 60335-1
UL 60335-2-40:Annex JJ
Product certifications: CB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque: 18 N.m
Height: 193 mm
Width: 143 mm
Depth: 193 mm
Net weight: 4.2 kg
Complementary
IP degree of protection: IP2X front face with shrouds conforming to IEC 60529
IP2X front face with shrouds conforming to VDE 0106
Ambient air temperature for operation: -25…60 °C
Ambient air temperature for storage: -60…80 °C
Mechanical robustness: Vibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
Colour: Dark grey
Protective treatment: TH
Permissible ambient air temperature around the device: -40…70 °C at Uc
Contractual warranty
Warranty: 18 months