TeSys K contactor – 3P – AC-3 <= 440 V 12 A – 1 NC aux. – 220…230 V AC coil
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 220V 50/60Hz AC coil, 1NC built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Main
Range: TeSys
Product or component type: Contactor
Device short name: LC1K
Device application: Control
Contactor application: Resistive load
Motor control
Utilisation category: AC-3
AC-3e
AC-1
AC-4
Poles description: 3P
power pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit: <= 690 V AC <= 400 Hz
Signalling circuit: <= 690 V AC <= 400 Hz
[Ie] rated operational current: 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit
Control circuit type: AC at 50/60 Hz
[Uc] control circuit voltage: 220…230 V AC 50/60 Hz
Motor power kW: 3 kW at 220…230 V AC 50/60 Hz AC-3
5.5 kW at 380…415 V AC 50/60 Hz AC-3
5.5 kW at 440 V AC 50/60 Hz AC-3
4 kW at 690 V AC 50/60 Hz AC-3
3 kW at 220…230 V AC 50/60 Hz AC-3e
5.5 kW at 380…415 V AC 50/60 Hz AC-3e
5.5 kW at 440 V AC 50/60 Hz AC-3e
4 kW at 690 V AC 50/60 Hz AC-3e
3 kW at 220…230 V AC 50/60 Hz AC-4
5.5 kW at 380…415 V AC 50/60 Hz AC-4
5.5 kW at 440 V AC 50/60 Hz AC-4
4 kW at 690 V AC 50/60 Hz AC-4
Auxiliary contact composition: 1 NC
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 20 A (at 60 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity: 144 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity: 110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current: 115 A 50 °C – 1 s for power circuit
105 A 50 °C – 5 s for power circuit
100 A 50 °C – 10 s for power circuit
75 A 50 °C – 30 s for power circuit
55 A 50 °C – 1 min for power circuit
50 A 50 °C – 3 min for power circuit
25 A 50 °C – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating: 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance: 3 mOhm – Ith 20 A 50 Hz for power circuit
Insulation resistance: > 10 MOhm for signalling circuit
Inrush power in VA: 30 VA (at 20 °C)
Hold-in power consumption in VA: 4.5 VA (at 20 °C)
Heat dissipation: 1.3 W
Control circuit voltage limits: Operational: 0.8…1.15 Uc (at <50 °C)
Drop-out: >= 0.20 Uc (at <50 °C)
Connections – terminals: Screw clamp terminals 1 cable(s) 1.5…4 mm²solid
Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1.5…4 mm²solid
Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
Maximum operating rate: 3600 cyc/h
Coil technology: Without built-in suppressor module
Auxiliary contacts type: type instantaneous 1 NC
Signalling circuit frequency: <= 400 Hz
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Operating time: 10…20 ms coil de-energisation and NO opening
10…20 ms coil energisation and NO closing
Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Non overlap distance: 0.5 mm
Mechanical durability: 10 Mcycles
Electrical durability: 1.3 Mcycles 12 A AC-3 at Ue <= 440 V
1.3 Mcycles 12 A AC-3e at Ue <= 440 V
0.3 Mcycles 20 A AC-1 at Ue <= 690 V
0.02 Mcycles 72 A AC-4 at Ue <= 440 V
Mechanical robustness: Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Height: 58 mm
Width: 45 mm
Depth: 57 mm
Complementary
Standards: EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
Product certifications: CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Protective treatment: TC conforming to IEC 60068
TC conforming to DIN 50016
Operating altitude: 2000 m without derating
Flame retardance: V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Environment
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 4.800 cm
Package 1 Width: 6.200 cm
Package 1 Length: 6.500 cm
Package 1 Weight: 177.700 g
Unit Type of Package 2: S02
Number of Units in Package 2: 50
Package 2 Height: 15.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 9.143 kg
Unit Type of Package 3: P06
Number of Units in Package 3: 800
Package 3 Height: 75.000 cm
Package 3 Width: 80.000 cm
Package 3 Length: 60.000 cm
Package 3 Weight: 154.294 kg
Packing Units