Description
Description
Start-stop control by rotary knob guaranteed for 100 000 cycles AC-3. It provides a thermal-magnetic protection with a thermal setting range 0.16-0.25A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX). Start-stop control by rotary knob guaranteed for 100 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
Main
Range: TeSys Deca
Product name: TeSys GV2
Product or component type: Motor circuit breaker
Device short name: GV2P
Device application: Motor protection
Trip unit technology: Thermal-magnetic
Poles description: 3P
Network type: AC
Utilisation category: Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency: 50/60 Hz conforming to IEC 60947-2
Motor power kW: 0.06 kW at 400/415 V AC 50/60 Hz
Breaking capacity: 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control type: Rotary handle
[In] rated current: 0.25 A
Thermal protection adjustment range: 0.16…0.25 A conforming to IEC 60947-2
Magnetic tripping current: 3.08 A
[Ith] conventional free air thermal current: 0.25 A conforming to IEC 60947-2
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Suitability for isolation: Yes conforming to IEC 60947-1
Power dissipation per pole: 2.5 W
Mechanical durability: 100000 cycles
Electrical durability: 100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated duty: Uninterrupted conforming to IEC 60947-4-1
Connections – terminals: Power circuit: screw clamp terminal 2 cable(s) 1…6 mm² – solid
Power circuit: screw clamp terminal 2 cable(s) 1.5…6 mm² – flexible without cable end
Power circuit: screw clamp terminal 2 cable(s) 1…4 mm² – flexible with cable end
Tightening torque: 1.7 N.m – on screw clamp terminal
Fixing mode: 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 2 x M4 screws)
Mounting position: Horizontal
Vertical
Width: 45 mm
Height: 89 mm
Depth: 97 mm
Colour: Dark grey
Complementary
Standards: EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC/EN 60335-2-40:Annex JJ
IEC/EN 60335-1:Clause 30.2
Product certifications: CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
RINA
DNV-GL
UKCA
IK degree of protection: IK04
IP degree of protection: IP20 conforming to IEC 60529
Climatic withstand: conforming to IACS E10
Ambient air temperature for storage: -40…80 °C
Fire resistance: 960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation: -20…60 °C
Mechanical robustness: Shocks: 30 Gn for 11 ms
Vibrations: 5 Gn, 5…150 Hz
Operating altitude: <= 2000 m
Environment
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 4.700 cm
Package 1 Width: 9.300 cm
Package 1 Length: 10.000 cm
Package 1 Weight: 262.000 g
Unit Type of Package 2: S02
Number of Units in Package 2: 20
Package 2 Height: 15.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 5.570 kg
Contractual warranty
Warranty (in months): 18