Description
Description
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 150A/1000V AC-3 (75kW@400V). It provides a 380V 50/60Hz AC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), 2 inputs screw connectors for power connection and screw clamp terminals for control. For operating rates until 1200 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (120mm width), mounting on 2 DIN-rails or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications
Range: TeSys
Range of product: TeSys Deca
Product or component type: Contactor
Device short name: LC1D
Contactor application: Motor control
Resistive load
Utilisation category: AC-3
AC-3e
AC-1
AC-4
Poles description: 3P
[Ue] rated operational voltage: Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 300 V DC
[Ie] rated operational current: 200 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
150 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
150 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[Uc] control circuit voltage: 380 V AC 50/60 Hz
Main
Motor power kW: 40 kW at 220/230 V AC 50/60 Hz (AC-3)
75 kW at 380/400 V AC 50/60 Hz (AC-3)
80 kW at 415/440 V AC 50/60 Hz (AC-3)
90 kW at 500 V AC 50/60 Hz (AC-3)
100 kW at 660/690 V AC 50/60 Hz (AC-3)
75 kW at 1000 V AC 50/60 Hz (AC-3)
40 kW at 220/230 V AC 50/60 Hz (AC-3e)
75 kW at 380/400 V AC 50/60 Hz (AC-3e)
80 kW at 415/440 V AC 50/60 Hz (AC-3e)
90 kW at 500 V AC 50/60 Hz (AC-3e)
100 kW at 660/690 V AC 50/60 Hz (AC-3e)
75 kW at 1000 V AC 50/60 Hz (AC-3e)
22 kW at 400 V AC 50/60 Hz (AC-4)
Motor power hp: 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors
50 hp at 230/240 V AC 50/60 Hz for 3 phases motors
100 hp at 460/480 V AC 50/60 Hz for 3 phases motors
125 hp at 575/600 V AC 50/60 Hz for 3 phases motors
Compatibility code: LC1D
Pole contact composition: 3 NO
Protective cover: With
[Ith] conventional free air thermal current: 200 A (at 60 °C) for power circuit
Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1660 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity: 1400 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 250 A 40 °C – 10 min for power circuit
580 A 40 °C – 1 min for power circuit
1200 A 40 °C – 10 s for power circuit
1400 A 40 °C – 1 s for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V coordination type 1 for power circuit
250 A gG at <= 690 V coordination type 2 for power circuit
Average impedance: 0.6 mOhm – Ith 200 A 50 Hz for power circuit
Power dissipation per pole: 24 W AC-1
13.5 W AC-3
13.5 W AC-3e
[Ui] rated insulation voltage: Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Overvoltage category: III
Pollution degree: 3
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947
Safety reliability level: B10d = 684932 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 10000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability: 8 Mcycles
Electrical durability: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V
1 Mcycles 200 A AC-1 at Ue <= 440 V
0.85 Mcycles 150 A AC-3e at Ue <= 440 V
Control circuit type: AC at 50/60 Hz
Coil technology: Built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits: 0.3…0.5 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.15 Uc (-40…55 °C):operational AC 50/60 Hz
1…1.15 Uc (55…70 °C):operational AC 50/60 Hz
Inrush power in VA: 280…350 VA 60 Hz cos phi 0.9 (at 20 °C)
280…350 VA 50 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA: 2…18 VA 60 Hz cos phi 0.9 (at 20 °C)
2…18 VA 50 Hz cos phi 0.9 (at 20 °C)
Heat dissipation: 3…4.5 W at 50/60 Hz
Operating time: 20…35 ms closing
40…75 ms opening
Maximum operating rate: 1200 cyc/h at 60 °C
Connections – terminals: Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…2.5 mm² – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: solid without cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 10…120 mm² – cable stiffness: solid without cable end
Power circuit: connector 2 10…50 mm² – cable stiffness: solid without cable end
Tightening torque: Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Auxiliary contact composition: 1 NO + 1 NC
Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency: 25…400 Hz
Minimum switching voltage: 17 V for signalling circuit
Minimum switching current: 5 mA for signalling circuit
Insulation resistance: > 10 MOhm for signalling circuit
Non-overlap time: 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting support: Rail
Plate
Complementary
Standards: CSA C22.2 No 14
EN 60947-4-1
IEC 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
Product certifications: UL
CCC
CSA
CE
UKCA
Marine
EAC
IP degree of protection: IP20 front face conforming to IEC 60529
Protective treatment: TH conforming to IEC 60068-2-30
Climatic withstand: conforming to IACS E10 exposure to damp heat
Permissible ambient air temperature around the device: -40…60 °C
60…70 °C with derating
Operating altitude: 0…3000 m
Fire resistance: 850 °C conforming to IEC 60695-2-1
Flame retardance: V1 conforming to UL 94
Mechanical robustness: Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (6 Gn for 11 ms)
Height: 158 mm
Width: 120 mm
Depth: 136 mm
Net weight: 2.5 kg
Environment
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 19.500 cm
Package 1 Width: 17.000 cm
Package 1 Length: 20.500 cm
Package 1 Weight: 2.487 kg
Unit Type of Package 2: S04
Number of Units in Package 2: 4
Package 2 Height: 30.000 cm
Package 2 Width: 40.000 cm
Package 2 Length: 60.000 cm
Package 2 Weight: 10.735 kg
Contractual warranty
Warranty (in months): 18