Description
AF80-30-00-12 – Block Contactor (ABB)
The AF80-30-00-12 is a 3 pole – 1000 V IEC or 600 UL contactor with screw terminals, controlling motors up to 37 kW / 400 V AC (AC-3) or 60 hp / 480 V UL and switching power circuits up to 125 A (AC-1) or 105 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
General Information
Manufacturer: ABB
Extended Product Type: AF80-30-00-12
Product ID: 1SBL397001R1200
EAN / GTIN: 3471523132924
Catalog Description: AF80-30-00-12 48-130V50/60HZ-DC Contactor
Product Name: Block Contactor
Ordering
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Dimensions
Product Net Width: 7 cm
Product Net Depth / Length: 11.6 cm
Product Net Height: 12.55 cm
Product Net Weight: 1.22 kg
Technical
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Number of Poles: 3P
Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency (f): Control Circuit 50 / 60 Hz; Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
Rated Operational Current AC-1 (Ie): (690 V) 40 °C 125 A; (690 V) 60 °C 100 A; (690 V) 70 °C 85 A
Rated Operational Current AC-3 (Ie): (415 V) 60 °C 80 A; (440 V) 60 °C 80 A; (500 V) 60 °C 65 A; (690 V) 60 °C 49 A; (1000 V) 60 °C 25 A; (380 / 400 V) 60 °C 80 A; (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current AC-3e (Ie): (415 V) 60 °C 80 A; (440 V) 60 °C 80 A; (500 V) 60 °C 65 A; (690 V) 60 °C 49 A; (380 / 400 V) 60 °C 80 A; (220 / 230 / 240 V) 60 °C 80 A
Rated Operational Current DC-1, DC-3, DC-5 (Ie): 125 A at 40 °C, 100 A at 60 °C, 85 A at 70 °C (72 V 1/2/3 poles in series; 110 V 2/3 poles in series; 220 V 3 poles in series)
Rated Operational Power AC-3 (Pe): (400 V) 37 kW; (415 V) 45 kW; (440 V) 45 kW; (500 V) 45 kW; (690 V) 45 kW; (1000 V) 35 kW; (380 / 400 V) 37 kW; (220 / 230 / 240 V) 22 kW
Rated Operational Power AC-3e (Pe): (415 V) 45 kW; (440 V) 45 kW; (500 V) 45 kW; (690 V) 45 kW; (380 / 400 V) 37 kW; (220 / 230 / 240 V) 22 kW
Rated Short-time Withstand Current Low Voltage (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State: 10 s 780 A; 15 min 140 A; 1 min 300 A; 1 s 1200 A; 30 s 450 A
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A; at 690 V 750 A
Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 1000 V; acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp): 8 kV
Maximum Electrical Switching Frequency: (AC-1) 600 cycles per hour; (AC-2 / AC-4) 150 cycles per hour; (AC-3) 1200 cycles per hour
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 50 Hz 48 … 130 V; 60 Hz 48 … 130 V; DC Operation 48 … 130 V
Coil Consumption: Average Holding Value 50 / 60 Hz 4 V·A; 50 Hz 4 V·A; 60 Hz 4 V·A; DC 2 W; from Warm State 2 W
Power Loss: at Rated Operating Conditions AC-1 per Pole 7.6 W; AC-3 per Pole 3 W
Operate Time: Coil De-energization and NC Contact Closing 19 … 105 ms; Coil De-energization and NO Contact Opening 17 … 100 ms; Coil Energization and NC Contact Opening 38 … 95 ms; Coil Energization and NO Contact Closing 42 … 100 ms
Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied): 2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 6 … 50 mm²; Flexible with Insulated Ferrule 1/2x 6 … 50 mm²; Rigid Stranded 1x 6 … 70 mm²; Rigid Stranded 2x 6 … 50 mm²
Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 … 2.5 mm²; Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²; Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²; Rigid Solid 1/2x 1 … 2.5 mm²; Rigid Stranded 1/2x 1 … 2.5 mm²
Wire Stripping Length: Control Circuit 1 cm; Main Circuit 1.7 cm
Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20; Main Terminals IP10
Recommended Screw Driver: Pozidriv PZ
Tightening Torque: Control Circuit 1.2 N·m; Main Circuit 6 N·m
Terminal Type: Screw Terminals
Technical UL/CSA
NEMA Size: 3
Continuous Current Rating NEMA: 90 A
Horsepower Rating NEMA: (200 V AC) Three Phase 25 Hp; (230 V AC) Three Phase 30 Hp; (460 V AC) Three Phase 50 Hp; (575 V AC) Three Phase 50 Hp
Maximum Operating Voltage UL/CSA: Main Circuit 600 V
General Use Rating UL/CSA: (600 V AC) 105 A
Horsepower Rating UL/CSA: (120 V AC) Single Phase 7-1/2 hp; (200 … 208 V AC) Three Phase 25 hp; (220 … 240 V AC) Three Phase 30 hp; (240 V AC) Single Phase 15 hp; (440 … 480 V AC) Three Phase 60 hp; (550 … 600 V AC) Three Phase 75 hp
Connecting Capacity Main Circuit UL/CSA: Rigid Stranded 1/2x 6-1 AWG
Connecting Capacity Control Circuit UL/CSA: Rigid Solid 1/2x 18-14 AWG; Rigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA: Control Circuit 11 in·lb; Main Circuit 53 in·lb
Full Load Amps Motor Use: (120 V AC) Single Phase 80 A; (200 … 208 V AC) Three Phase 78.2 A; (220 … 240 V AC) Three Phase 80 A; (240 V AC) Single Phase 68 A; (440 … 480 V AC) Three Phase 77 A; (550 … 600 V AC) Three Phase 77 A
Environmental
Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -40 … 70 °C; without Thermal O/L Relay -40 … 70 °C; for Storage -60 … +80 °C
Climatic Withstand: Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible: Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction A 25 g; B1 25 g; B2 15 g; C1 25 g; C2 25 g; Open, Shock Direction B1 5 g
Resistance to Vibrations: 3g Closed Position & 3g Open Position 5 … 300 Hz
Pollution Degree: 3
Material Compliance
RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B: Business To Business
WEEE Category: 5. Small Equipment (No External Dimension More Than 50 cm)
Available declarations: CMRT, REACH, RoHS II, TSCA
ABB EcoSolutions
ABB EcoSolutions: Yes
Waste To Landfill Target: No non-hazardous waste is sent to a landfill
Improved Energy Efficiency for Customers: Product Efficiency – Product considered more energy-efficient compared to similar product on market or older products from the same line; Product requires less energy to operate compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555: 91.9 %
Certificates and Declarations
A2L (UL-US, UL-CA), ABS, BV, CB, CCC, Declaration of Conformity CCC, CE, UKCA, DNV, LR, RINA, RMRS, UL Certificate, UL Listing Card (UL_E312527).
Container Information
Package Level 1 Units: box 1 piece
Package Level 1 Width: 15 cm
Package Level 1 Depth / Length: 15 cm
Package Level 1 Height: 10.3 cm
Package Level 1 Gross Weight: 1.34 kg
Package Level 1 EAN: 3471523132924
External Classifications and Standards
Object Classification Code: Q
ETIM 7 / 8 / 9: EC000066 – Power contactor, AC switching
eClass: V11.0 : 27371003
UNSPSC: 39121529
IDEA Granular Category Code (IGCC): 4758 >> Iec Contactors
E-Number (Finland): 3707121
E-Number (Sweden): 3210052
Datasheet and Documents
Data Sheet / Technical Information: 1SBC100214C0202 – Main catalog Motor protection and control Manual motor starters, contactors and overload relays (PDF) – Edition 2024. Installation instructions AF(C)40(B)…96(B)-30 Contactors, CA4, CAL4, CAT4, CC4, LDC4 Accessories. Contactors and Overload relays guide.