Description
E2.2N 1600 Ekip Dip LI 4p F HR
Extended Product Type: E2.2N 1600 Ekip Dip LI 4p F HR
Product ID: 1SDA071621R1
EAN: 8015644754716
Catalog Description: E2.2N 1600 Ekip Dip LI 4p F HR
Detailed Description: C.BREAKER SACE EMAX2 E2.2N 1600 FIXED FOUR-POLE WITH TERMINALS REAR HORIZONTAL AND SOLID-STATE RELEASE IN AC EKIP/DIP-LI R 1600 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED
ABB EcoSolutions: Yes
Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions: Disassembly instructions Emax 2 E2.2
Environmental Product Declaration: EPD Emax 2 E2.2 IEC (IT), EPD Emax 2 E2.2 IEC (CN)
Extended Product Lifetime: Lifetime Extension Services are Offered
Recyclability Rate acc. to EN45555: 79.1 %
Material Compliance: REACh Declaration ABB Sace circuit breakers; RoHS Declaration ABB Sace circuit breakers; Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019; Conflict Minerals Reporting Template (CMRT); Toxic Substances Control Act (TSCA) declaration
SCIP: 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental Information: Breakers – Packaging disposal information
Order Code US and Canada: ZBNSEJBA000A000000XX
Minimum Order Quantity: 1 piece
Customs Tariff Code: 85362090
Dimensions: Width 36.6 cm; Height 37.1 cm; Depth/Length 27 cm
Weight: Net 53 kg
Package Dimensions: Width 51.5 cm; Height 61 cm; Depth/Length 61.5 cm
Package Gross Weight: 58 kg
Product Main Type: SACE Emax 2
Product Name: Air Circuit Breaker
Product Type: Air Circuit Breaker
Version: F
Connecting Capacity: 1200 mm²
Current Type: AC
Electrical Durability: Ue =< 440 V 12000 cycle
Ue = 500 … 690 V 10000 cycle
30 cycles per hour
Mechanical Durability: 25000 cycle
60 cycles per hour
Neutral Pole Current: 100 % Iu
Number of Poles: 4
Power Loss: 136 W
Rated Current (In): 1600 A
Rated Impulse Withstand Voltage (Uimp): 12 kV acc. to IEC 60947-2
Rated Insulation Voltage (Ui): AC 1000 V
Rated Operational Voltage: 690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics): 66 kA for 220 to 690 V AC
Rated Service Short-Circuit Breaking Capacity, in % of Icu: 100 %
Rated Short-time Withstand Current Low Voltage (Icw): 66 kA for 1 s; 50 kA for 3 s
Rated Ultimate Short-Circuit Breaking Capacity (Icu): 66 kA for 400 to 690 V AC
Rated Uninterrupted Current (Iu): 1600 A
Rated Voltage (Ur): 690 V
Recommended Screw Driver: M12
Release: Ekip Dip LI (EL type)
Short-Circuit Performance Level: N
Standards: IEC
Sub-type: E2.2
Suitable for IT Networks: Yes, 690V
Terminal Connection Type: Rear flat Horizontal
Terminal Type: Bolt
Tightening Torque: 70 N·m
Certificates: ATEX, CSA, UL, VDE – No certification needed
Technical Documents: SACE Emax 2 low voltage air circuit-breakers, CE Declaration, EU Data Act Compliance
Mechanical Drawings and Wiring Diagram Available