Description
DS201 M C40 AC30 Residual Current Circuit Breaker with Overcurrent Protection
The DS201 series is a 1P+N RCBO in two-modules width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct contacts.
Type of Residual Current: Type AC
Test Voltage (Ut): 170 … 264 V
Dielectric Test Voltage: 2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu): 15 kA
Rated Residual Breaking Capacity (IΔm): EN 61009-1 6000 A, IEC 61009-1 4500 A
Rated Service Short-Circuit Breaking Capacity (Ics): 11.2 kA
Maximum Surge Current: 0 kA
Power Supply Connection: Arbitrary
Contact Position Indication: Red ON / Green OFF
Energy Limiting Class: 3
Electrical Endurance: 10000 cycle
Mechanical Endurance: 20000 cycle
Number of Protected Poles: 1
Number of Poles: 1P+N
Number of Modular Spacings per DIN Rail: 2
Fault Indication: Blue Flag on Toggle
Operating Characteristic: Instantaneous
Position of Neutral Terminals: Right
Tightening Torque: 2.8 N·m
Accessory Type: Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Actuator Type: Toggle – Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Housing Type: Insulation group I – II, RAL 7035
Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
Accessories Available: Yes
Number of Batteries: 0
Connecting Capacity: Busbar 10 … 10 mm², Stranded 0.75 … 25 mm², Flexible with Ferrule 0.75 … 16 mm², Flexible 0.75 … 16 mm²
Wire Stripping Length: 12 mm
Terminal Type: Screw Terminals
Tripping Characteristic: C
Rated Operational Voltage: acc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp): 4 kV
Input Voltage Type: AC
Rated Current (In): 40 A
Rated Residual Current: 30 mA
Rated Short-Circuit Capacity: 10 kA
Rated Conditional Short-Circuit Current (Inc): 15 kA
Rated Frequency (f): 50 / 60 Hz
Power Loss: Average per Pole 4.6 W, Phase Pole 5.0 W, Neutral Pole 4.1 W, Total 9.1 W
Overvoltage Category: III
RoHS Compliance: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
REACH Compliance: True – contains substances > 0.1 mass percentage
Ambient Air Temperature Operation: -25 … 55 °C
Reference Ambient Air Temperature: 30 °C
Degree of Protection: IP20 / IP40
Pollution Degree: 2
Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
Resistance to Vibrations: 20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27: 25g 2 shocks 13 ms
Dimensions (W x H x D): 3.5 cm x 8.5 cm x 6.9 cm
Product Net Weight: 200 g
Package Level 1 Units: box 1 piece
Package Level 1 Gross Weight: 225 g
Customs Tariff Code: 39121601