Description
Block Contactor AX09-30-01-84
Manufacturer: ABB
Product ID: 1SBL901074R8401
EAN: 3471522392848
Description: AX09-30-01-84 110V50Hz/110-120V60Hz Contactor. AX09…AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: 3 main poles and 1 built-in auxiliary contact; control circuit: AC operated; add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Dimensions (cm): Width 4.4, Depth/Length 7.4, Height 7.4
Weight (kg): 0.326
Technical Data:
Number of Main Contacts NO: 3, Number of Main Contacts NC: 0, Number of Auxiliary Contacts NO: 0, Number of Auxiliary Contacts NC: 1
Rated Operational Voltage: Auxiliary Circuit 690 V, Main Circuit 690 V
Rated Frequency: Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): according to IEC 60947-4-1, Open Contactors at 40 °C 24 A; IEC 60947-5-1 at 40 °C 16 A
Rated Operational Current AC-1 (Ie): 220 / 240 V at 55 °C 22 A; 690 V at 40 °C 22 A; 690 V at 70 °C 18 A
Rated Operational Current AC-3 (Ie): 415-500 V at 55 °C 9 A; 690 V at 55 °C 7 A
Rated Operational Current AC-15 (Ie): 500 V NC 2 A; 690 V 2 A; 24 / 127 V 6 A; 220 / 400 V up to 4 A
Rated Operational Current DC-13 (Ie): 24 V 6 A / 144 W; up to 500 V 2 A / 144 W
Rated Operational Power AC-3 (Pe): up to 690 V 5.5 kW
Rated Short-time Withstand Current Low Voltage (Icw): various values up to 250 A depending on time and conditions
Maximum Breaking Capacity: 250 A at 440 V, 90 A at 690 V with cos phi=0.45 (0.35 for Ie > 100 A)
Rated Insulation Voltage Ui: 690 V
Rated Impulse Withstand Voltage Uimp: Auxiliary Circuit 6 kV
Max Electrical Switching Frequency: AC-1 600 cycles/hour; AC-15 1200 cycles/hour; AC-3 1200 cycles/hour; DC-13 900 cycles/hour
Max Mechanical Switching Frequency: 3600 cycles/hour
Rated Control Circuit Voltage Uc: 50 Hz 110 V; 60 Hz 110 to 120 V
Power Loss: AC-1 per Pole 0.8 W; AC-3 per Pole 0.1 W
Operate Time: coil de-energization and contact operations range from 4 to 26 ms depending on contact type
Degree of Protection (IP): Auxiliary Terminals IP20; Coil Terminals IP20; Main Terminals IP20 as per IEC standards
Tightening Torque: 1 N·m for Auxiliary, Control and Main Circuits
Terminal Type: Screw Terminals
UL/CSA Rating: 600 V AC 21 A
Horsepower Rating UL/CSA: single phase and three phase motors from 1/2 hp up to 7.5 hp depending on voltage
Full Load Amps Motor Use UL/CSA: ranges from 6.8 A to 10 A depending on voltage and phase
Environmental Conditions: Ambient temperatures from -25 to 70 °C depending on application; storage -60 to +80 °C; maximum operating altitude 3000 m without derating
Customs Tariff Code: 85364900