Description
DSE201 M C25 A100 – N Blue
Residual Current Circuit Breaker with Overcurrent Protection DSE201 M – 1P+N – 100 mA – 25 A – C – Type A
1P+N electronic RCBO in one-module width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA). Presence of neutral (blue or black) and functional earth (white) flying leads. The neutral is unswitched.
Type of Residual Current: Type A
Electrical Ratings: Maximum Operating Voltage 264 V, Test Voltage 195 – 264 V, Dielectric Test Voltage 2 kV, Rated Ultimate Short-Circuit Breaking Capacity 15000 A, Rated Residual Breaking Capacity 10000 A, Rated Service Short-Circuit Breaking Capacity 7500 A, Maximum Surge Current 250 A.
Power Supply Connection: Bottom
Contact Position Indication: Red ON / Green OFF
Energy Limiting Class: 3
Electrical Endurance: 10000 cycles, Mechanical Endurance 20000 cycles
Number of Protected Poles: 1 (1P+N)
Number of Modular Spacings per DIN Rail: 1
Fault Indication: Blue Window
Operating Characteristic: Instantaneous
Position of Neutral Terminals: Right
Tightening Torque: Top 1.2 N·m, Bottom 2.8 N·m
Accessories: Auxiliary contact, Auxiliary/Signal contact, Shunt trip, Undervoltage release, Overvoltage release, Bottom fitting auxiliary contact
Actuator Type: Toggle – Insulation group II, black, sealable in ON-OFF positions
Earthing Switch Type: Undelayed
Cover Type: Insulation group II, RAL 7035
Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
Connecting Capacity: Busbar 10 mm², Rigid 1 to 35 mm², Flexible 1 to 16 mm²
Nominal Cross Section: Solid-Core 1 to 35 mm², Multi-Wired 1 to 25 mm²
Wire Stripping Length: Top 11 mm, Bottom 12.5 mm
Terminal Type: Screw Terminals
Tripping Characteristic: C
Operating Voltage: 240 V (IEC 60898-1)
Rated Insulation Voltage: 500 V (IEC/EN 60664-1)
Rated Impulse Withstand Voltage: 4 kV
Input Voltage Type: AC
Rated Current: 25 A
Rated Residual Current: 100 mA
Rated Short-Circuit Capacity: 10000 A
Rated Conditional Short-Circuit Current: 10000 A
Nominal Frequency: 50 to 60 Hz
Power Loss: Total 3.3 W
Overvoltage Category: III
Environmental: Operation -25 to 55 °C, Reference Ambient Air Temperature 30 °C, Protection IP20 and IP40, Pollution Degree 2, 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %, Vibration resistance 20 cycles with load 0.8 In: 5g or 0.35mm 5 to 150 Hz, Shock resistance 30g / 2 shocks / 13 ms.
Dimensions: Width 1.8 cm, Height 11.5 cm, Depth 6.9 cm, Built-In Depth 6.89 cm
Net Weight: 200 g
Packaging: box 1 piece, Gross Weight 0.22 kg
Mounting Type: DIN-Rail, Mounting Position: Any
Standards: IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1, BS EN 61009-1
Customs Tariff Code: 85362010