Product Name: Eaton Moeller series BZM – Molded case circuit breaker
Model Code: BZME1-A25-BT
Description: Eaton Moeller series Circuit breaker BZME1, Three-pole, 25 A, 415 V, Box terminal
Dimensions and Weight
Length/Depth: 13.02 cm, Height: 8.6 cm, Width: 7.5 cm, Weight: 0.83 kg
Electrical Specifications
Amperage Rating: 25 A, Voltage Rating: 415 V – 415 V, Rated operational current for specified heat dissipation: 25 A
Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz: 18 kA
Instantaneous current setting (Ii) range: 320 A – 480 A
Short delay current setting (Isd) and Overload current setting (Ir) are both 0 A minimum and maximum
Features and Mechanical
Type: Circuit breaker, Number of poles: Three-pole
Handle type: Rocker lever, Position of connection for main current circuit: Front side
Features: Protection unit
Mounting and Protection
Mounting Method: DIN rail (top hat rail) mounting optional; Built-in device fixed built-in technique
Degree of protection: IP20, Electrical connection type of main circuit: Frame clamp, Overvoltage category: III
Environmental and Compliance
Pollution degree: 3
Compliances: RoHS conform
Other Technical Notes
Temperature rise: The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Short-circuit rating: Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Electromagnetic compatibility: Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Mechanical function: The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Corrosion resistance, thermal stability of enclosures, resistance to normal and abnormal heat/fire effects, resistance to UV radiation, inscriptions and clearances and creepage distances all meet the product standard’s requirements.
Lifting and mechanical impact tests do not apply as the entire switchgear needs evaluation.
Incorporation of switching devices, protection against electric shock, degree of protection of assemblies do not apply since the entire switchgear needs evaluation.
Internal electrical circuits, connections for external conductors, power-frequency electric strength, impulse withstand voltage and testing of enclosures made of insulating material are the panel builder’s responsibility.
Equipment heat dissipation, current-dependent: 6.2 W
Number of auxiliary contacts (change-over, normally closed, normally open): 0
Customs Tariff Code
85362000