Description
Product Name
Eaton Moeller series Power Defense molded case circuit-breaker
Catalog Number
PDE13F0050VAAJ
EAN
9010238098152
Model Code
PDE13F0050VAAJ
Dimensions and Weight
Length/Depth: 14.5 cm, Height: 8.7 cm, Width: 8.9 cm, Weight: 1.046 kg
Compliance and Certifications
Compliances: RoHS conform, Certifications: IEC IEC/EN 60947
Delivery Program
Circuit breaker frame type: PDE1, Amperage Rating: 50 A, Number of poles: Three-pole
Technical Data – Electrical
Voltage rating: 220 V – 440 V, Voltage rating (DC): 250 V, Max. rated operation voltage Ue AC: 440 V, Rated insulation voltage (Ui): 800 V AC, Rated impulse withstand voltage (Uimp) at auxiliary contacts: 6000 V, Rated impulse withstand voltage (Uimp) at main contacts: 6000 V, Rated current (Iu): 50 A, Instantaneous current setting (Ii) – min and max: 500 A, Overload current setting (Ir) – min: 40 A, max: 50 A, Rated short-circuit breaking capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz: 35 kA, at 400/415 V, 50/60 Hz: 25 kA, at 440 V, 50/60 Hz: 15 kA, Electrical connection type of main circuit: Frame clamp, Overvoltage category: III, Utilization category: A, Pollution degree: 3
Technical Data – Mechanical
Type: Circuit breaker, Release system: Thermomagnetic release, Mounting Method: DIN rail (top hat rail) mounting optional Complete device in housing Fixed, Degree of protection: IP2X, Number of auxiliary contacts (change-over, normally closed, normally open): 0, Number of operations per hour – max: 120, Handle type: Rocker lever, Position of connection for main current circuit: Front side, Direction of incoming supply: Vertical and 90° in all directions, Standard terminals: Box terminal, Lifespan, mechanical: 25000 operations
Design verification as per IEC/EN 61439 – Technical Data
Ambient operating temperature – min: -20 °C, max: 70 °C, Ambient storage temperature – min: -20 °C, max: 70 °C
Design verification as per IEC/EN 61439
Corrosion resistance: Meets the product standard’s requirements., Verification of thermal stability of enclosures: Meets the product standard’s requirements., Verification of resistance of insulating materials to normal heat: Meets the product standard’s requirements., Resistance of insulating materials to abnormal heat/fire by internal electrical effects: Meets the product standard’s requirements., Resistance to ultra-violet (UV) radiation: Meets the product standard’s requirements., Lifting and Mechanical impact: Does not apply, since the entire switchgear needs to be evaluated., Inscriptions: Meets the product standard’s requirements., Degree of protection of assemblies: Does not apply, since the entire switchgear needs to be evaluated., Clearances and creepage distances: Meets the product standard’s requirements., Protection against electric shock, Incorporation of switching devices and components: Does not apply, Internal electrical circuits and connections, Connections for external conductors, Power-frequency electric strength, Impulse withstand voltage, Testing of enclosures made of insulating material: Is the panel builder’s responsibility., Temperature rise: The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices., Short-circuit rating, Electromagnetic compatibility: Is the panel builder’s responsibility. The specifications for the switchgear must be observed., Mechanical function: The device meets the requirements, provided the instructions are observed.
Additional Information
Features: Protection unit Motor drive optional, Functions: System and cable protection, Special features: Thermally and magnetically adjustable (calibrated at 50 °C)