Description
Eaton Moeller series Power Defense Molded Case Circuit Breaker
SKU: PDE23N0200TAAS
Product Name: Eaton Moeller series Power Defense molded case circuit-breaker
Catalog Number: PDE23N0200TAAS
EAN: 9008790969652
Dimensions (Length x Height x Width): 20.1 cm x 8.9 cm x 10.3 cm
Weight: 2.646 kg
Compliances: RoHS conform
Certifications: IEC IEC/EN 60947
Amperage Rating: 200 A
Voltage Rating: 220 V – 440 V AC
Circuit Breaker Frame Type: PDE2
Features: Protection unit Motor drive optional
Temperature Rise: The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Short Circuit Rating: Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Electromagnetic Compatibility: Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Mechanical Function: The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Corrosion Resistance: Meets the product standard’s requirements.
Verifications and Resistances: Verification of thermal stability of enclosures, resistance of insulating materials to normal heat, resistance to abnormal heat/fire by internal electrical effects, resistance to ultra-violet (UV) radiation meet the product standard’s requirements.
Lifting and Mechanical Impact: Do not apply, since the entire switchgear needs to be evaluated.
Inscriptions: Meets the product standard’s requirements.
Clearances and Creepage Distances: Meets the product standard’s requirements.
Protection Against Electric Shock and Incorporation of Switching Devices: Do not apply, since the entire switchgear needs to be evaluated.
Internal Electrical Circuits and Connections: Is the panel builder’s responsibility.
Pollution Degree: 3
Lifespan, Mechanical: 20000 operations
Utilization Category: A
Mounting Method: Complete device in housing DIN rail (top hat rail) mounting optional Fixed
Ambient Operating Temperature: -20 °C min to 70 °C max
Ambient Storage Temperature: -20 °C min to 70 °C max
Rated Current (Iu): 200 A
Max Rated Operation Voltage Ue AC: 440 V
Number of Poles: Three-pole
Degree of Protection: IP2X
Direction of Incoming Supply: Vertical and 90° in all directions
Electrical Connection Type of Main Circuit: Screw connection
Overvoltage Category: III
Functions: System and cable protection
Type: Circuit breaker
Special Features: Thermally and magnetically adjustable (calibrated at 40 °C)
Position of Connection for Main Current Circuit: Front side
Power Loss: 58 W
Release System: Thermomagnetic release
Handle Type: Rocker lever
Instantaneous Current Setting (Ii): Min 1000 A, Max 1600 A
Number of Operations per Hour – Max: 120
Overload Current Setting (Ir): Min 160 A, Max 200 A
Rated Short-Circuit Breaking Capacity Ics (IEC/EN 60947): 100 kA at 230 V 50/60 Hz, 70 kA at 400/415 V 50/60 Hz, 37 kA at 440 V 50/60 Hz
Standard Terminals: Screw terminal
Rated Impulse Withstand Voltage (Uimp): 4000 V at auxiliary contacts, 8000 V at main contacts
Voltage Rating (DC): 250 V
Rated Insulation Voltage (Ui): 800 V AC
Customs Tariff Code: 85362010