Product Name: Eaton Moeller series Power Defense molded case circuit-breaker
Catalog Number: PDE14G0080VAAJ
SKU: PDE14G0080VAAJ
EAN: 9010238098725
Description: Eaton Moeller series Power Defense – Molded Case Circuit Breaker. Circuit breaker, 80A, 36kA, 4p, 50°C, box terminal
Dimensions: Length 14.6 cm, Height 8.7 cm, Width 12.0 cm
Weight: 1.325 kg
Compliances: RoHS conform
Certifications: IEC IEC/EN 60947
Electrical Specifications
Amperage Rating: 80 A
Voltage Rating: 220 V – 440 V
Circuit Breaker Frame Type: PDE1
Features: Protection unit Motor drive optional
Rated Current (Iu): 80 A
Max Rated Operation Voltage Ue AC: 440 V
Number of Poles: Four-pole
Functions: System and cable protection
Type: Circuit breaker
Special Features: Thermally and magnetically adjustable (calibrated at 50 °C)
Standard Terminals: Box terminal
Voltage Rating (DC): 250 V
Rated Insulation Voltage (Ui): 800 V AC
Mechanical and Environmental Specifications
Mounting Method: Complete device in housing Fixed DIN rail (top hat rail) mounting optional
Degree of Protection: IP2X
Direction of Incoming Supply: Vertical and 90° in all directions
Electrical Connection Type of Main Circuit: Frame clamp
Overvoltage Category: III
Ambient Operating Temperature: Min -20 °C, Max 70 °C
Ambient Storage Temperature: Min -20 °C, Max 70 °C
Pollution Degree: 3
Mechanical Lifespan: 25000 operations
Performance and Protection
Power Loss: 36.1 W
Release System: Thermomagnetic release
Handle Type: Rocker lever
Instantaneous Current Setting (Ii): 800 A (min and max)
Number of Operations Per Hour – Max: 120
Overload Current Setting (Ir): Min 64 A, Max 80 A
Rated Short-Circuit Breaking Capacity Ics (IEC/EN 60947) at 230 V, 50/60 Hz: 50 kA
Rated Short-Circuit Breaking Capacity Ics (IEC/EN 60947) at 400/415 V, 50/60 Hz: 36 kA
Rated Short-Circuit Breaking Capacity Ics (IEC/EN 60947) at 440 V, 50/60 Hz: 22.5 kA
Rated Impulse Withstand Voltage (Uimp) at Auxiliary Contacts: 6000 V
Rated Impulse Withstand Voltage (Uimp) at Main Contacts: 6000 V
Additional Information
Temperature Rise: The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Short-Circuit Rating Responsibility: Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Electromagnetic Compatibility Responsibility: Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Mechanical Function: The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Corrosion Resistance: Meets the product standard’s requirements.
Verification of Thermal Stability of Enclosures: Meets the product standard’s requirements.
Verification of Resistance of Insulating Materials to Normal Heat: Meets the product standard’s requirements.
Resistance of Insulating Materials to Abnormal Heat/Fire by Internal Electrical Effects: Meets the product standard’s requirements.
Resistance to Ultra-Violet (UV) Radiation: Meets the product standard’s requirements.
Lifting and Mechanical Impact Applicability: Does not apply, since the entire switchgear needs to be evaluated.
Inscriptions: Meets the product standard’s requirements.
Clearances and Creepage Distances: Meets the product standard’s requirements.
Internal Electrical Circuits and Connections Responsibility: Is the panel builder’s responsibility.
Connections for External Conductors Responsibility: Is the panel builder’s responsibility.
Power-Frequency Electric Strength Responsibility: Is the panel builder’s responsibility.
Impulse Withstand Voltage Responsibility: Is the panel builder’s responsibility.
Testing of Enclosures Made of Insulating Material Responsibility: Is the panel builder’s responsibility.