| Weight |
1.41 kg |
| Dimensions |
22.2 × 8.8 × 6.95 cm |
| Product ID |
1SAE231111M0640
|
| Extended Product Type |
ESB25-40N-06
|
| Catalog Description |
ESB25-40N-06 Installation Contactor (NO) 25 A – 4 NO – 0 NC – 230 … 240 V – Control Circuit 400 Hz
|
| Minimum Order Quantity |
6
|
| Customs Tariff Code |
85365080
|
| Product Net Width cm |
3.6
|
| Product Net Depth Length cm |
6.5
|
| Product Net Height cm |
8.5
|
| Product Net Weight kg |
0.235
|
| Number of Main Contacts NO |
4
|
| Number of Main Contacts NC |
0
|
| Number of Auxiliary Contacts NO |
0
|
| Number of Auxiliary Contacts NC |
0
|
| Number of Poles |
4P
|
| Standards |
[
"IEC/EN 60947-1",
"IEC/EN 60947-4-1",
"IEC/EN 61095",
"UL 60947-1",
"UL 60947-4-1",
"IEC 60335-2-40 A2L"
]
|
| Rated Operational Voltage |
{
"Main_Circuit_DC": 220,
"Main_Circuit_AC": 400,
"Control_Circuit_Voltage": "230 … 240",
"Rated_Control_Circuit_Frequency_Hz": 400
}
|
| Rated Operational Current |
{
"AC-1_NO": 25,
"AC-3_230V_Single_Phase_NO": 9,
"AC-3_400V_Three_Phase_NO": 9,
"AC-7a_NO": 25,
"AC-7b_230V_Single_Phase_NO": 9,
"AC-7b_400V_Three_Phase_NO": 9
}
|
| Rated Operational Power |
{
"AC-1_230V_Single_Phase_NO_kW": 5.8,
"AC-1_400V_Three_Phase_NO_kW": 17.3,
"AC-3_230V_Single_Phase_NO_kW": 1.3,
"AC-3_400V_Three_Phase_NO_kW": 4,
"AC-7a_230V_Single_Phase_NO_kW": 5.8,
"AC-7a_400V_Three_Phase_NO_kW": 17.3,
"AC-7b_230V_Single_Phase_NO_kW": 1.3,
"AC-7b_400V_Three_Phase_NO_kW": 4
}
|
| Rated Breaking Capacity AC-3 |
8 x Ie / AC-3
|
| Rated Making Capacity AC-3 |
10 x Ie / AC-3
|
| Rated Short-time Withstand Current Low Voltage 10s A |
72
|
| Rated Insulation Voltage V |
500
|
| Rated Impulse Withstand Voltage kV |
6
|
| Electrical Durability Cycles |
{
"AC-1_NO": 130000,
"AC-3_NO": 500000,
"AC-7a_NO": 130000,
"AC-7b_NO": 500000
}
|
| Maximum Electrical Switching Frequency cycles per hour |
{
"AC-1": 300,
"AC-3": 600,
"AC-7a": 300,
"AC-7b": 600
}
|
| Mechanical Durability Cycles |
1000000
|
| Coil Operating Limits |
(acc. to IEC 60947-4-1) 0.85 … 1.1 x Uc (at θ ≤ 55 °C)
|
| Rated Control Circuit Voltage V |
230 … 240
|
| Coil Consumption |
{
"Average_Holding_Value_50_60_Hz_VA": 4,
"Average_Holding_Value_DC_W": 4,
"Average_Pull-in_Value_50_Hz_VA": 4,
"Average_Pull-in_Value_60_Hz_VA": 4,
"Average_Pull-in_Value_DC_W": 4
}
|
| Power Loss per Pole W |
2
|
| Mounting on DIN Rail |
[
"TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715",
"TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715"
]
|
| Connecting Capacity Main Circuit mm2 |
{
"Flexible_with_Ferrule_1x": "1.5 … 10",
"Flexible_with_Ferrule_2x": "1.5 … 2.5",
"Flexible_with_Insulated_Ferrule_1x": "1.5 … 10",
"Flexible_with_Insulated_Ferrule_2x": "1.5",
"Flexible_1x": "1.5 … 10",
"Flexible_2x": "1.5 … 4",
"Rigid_1x": "1.5 … 10",
"Rigid_2x": "1.5 … 4"
}
|
| Connecting Capacity Control Circuit mm2 |
{
"Flexible_with_Ferrule_1x": "1 … 2.5",
"Flexible_with_Ferrule_2x": "0.75 … 1",
"Flexible_with_Insulated_Ferrule_1x": "1 … 2.5",
"Flexible_with_Insulated_Ferrule_2x": "0.75 … 1",
"Flexible_1x": "1 … 4.0",
"Flexible_2x": "1 … 2.5",
"Rigid_1x": "1 … 4",
"Rigid_2x": "1 … 2.5"
}
|
| Wire Stripping Length mm |
{
"Control_Circuit": 7,
"Main_Circuit": 10
}
|
| Degree of Protection |
IP20
|
| Recommended Screw Driver |
{
"Control_Circuit": "Pozidriv 1",
"Main_Circuit": "Pozidriv 1"
}
|
| Tightening Torque Nm |
{
"Control_Circuit": 0.9,
"Main_Circuit": 1
}
|
| Terminal Type |
Screw Terminals
|
| Width in Number of Modular Spacings |
2
|
| Technical UL CSA |
{
"Maximum_Operating_Voltage_AC_V": 480,
"General_Use_Rating_A": "25",
"Horsepower_Rating_HP": {
"220-240V_AC_Single_Phase_NO": 1,
"220-240V_AC_Three_Phase_NO": 3,
"440-480V_AC_Single_Phase_NO": 2,
"440-480V_AC_Three_Phase_NO": 5
},
"Connecting_Capacity_Main_Circuit_AWG": [
"Solid 16-8",
"Stranded 16-8"
],
"Connecting_Capacity_Control_Circuit_AWG": [
"Solid 16-10",
"Stranded 16-10"
],
"Tightening_Torque_in_lb": {
"Control_Circuit": 8,
"Main_Circuit": 9
},
"Full_Load_Amps_Motor_Use_A": {
"220-240V_AC_Single_Phase_NO": 9.6,
"220-240V_AC_Three_Phase_NO": 9.6,
"440-480V_AC_Single_Phase_NO": 7.6,
"440-480V_AC_Three_Phase_NO": 7.6
}
}
|
| Environmental |
{
"Ambient_Air_Temperature_Operation_C": {
"Min": -25,
"Max": 55
},
"Ambient_Air_Temperature_Storage_C": {
"Min": -40,
"Max": 80
},
"Maximum_Operating_Altitude_m": 2000,
"Resistance_to_Shock": "11 ms Pulse 15g",
"Pollution_Degree": 3
}
|
| Material Compliance |
{
"Conflict_Minerals_Reporting_Template": true,
"REACH_Declaration": true,
"RoHS_Declaration": true,
"RoHS_Information": "Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019",
"TSCA_Compliance": true,
"WEEE_B2C_B2B": "Business To Consumer",
"WEEE_Category": "5. Small Equipment (No External Dimension More Than 50 cm)"
}
|
| ABB EcoSolutions |
{
"ABB_EcoSolutions": true,
"Site_Meeting_Group_Waste_To_Landfill_Target": "No non-hazardous waste is sent to a landfill",
"UL_2799_Zero_Waste_To_Landfill_Validation": true,
"End_Of_Life_Disassembling_Instructions": true,
"Environmental_Product_Declaration_EPD": true
}
|
| Certificates And Declarations |
[
"A2L Certificate – IEC",
"ABS Certificate",
"CB Certificate",
"CQC Certificate",
"Declaration of Conformity – CCC",
"Declaration of Conformity – CE",
"Declaration of Conformity – UKCA",
"DNV Certificate",
"EAC Certificate",
"NF Certificate",
"RINA Certificate",
"RMRS Certificate",
"UL Certificate"
]
|
| Package Level 1 Units |
6
|
| Package Level 1 Width cm |
8.8
|
| Package Level 1 Depth Length cm |
22.2
|
| Package Level 1 Height cm |
6.95
|
| Package Level 1 Gross Weight kg |
1.41
|
| Package Level 1 EAN |
4013614519703
|
| Package Level 2 EAN |
4013614567056
|
| Object Classification Code |
Q
|
| ETIM 7 |
EC001653 – Installation contactor for distribution board
|
| ETIM 8 |
EC001653 – Installation contactor for distribution board
|
| ETIM 9 |
EC001653 – Installation contactor for distribution board
|
| eClass |
V11.0 : 27142308
|
| UNSPSC |
39121529
|
| IDEA Granular Category Code IGCC |
4759 >> Installation contactor for distribution board
|