Description
EZC100N1025 – Circuit breaker, EasyPact EZC100N, TMD, 25A, 1 pole 1d
This is a 25A circuit breaker for EasyPact EZC100N. This product can work below rated operational voltage(Ue) 415 V AC at 50/60 Hz or 125 V DC network. The ultimate breaking capacity(Icu) is shown differently, depending on the condition of network, Ics=50% Icu if need to match. This version of product is designed one pole frame with detection on one pole, equipped with TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab (KEMA, ASEFA, TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure, and against safety risk by padlocking. The degree of protection is IP40 for direct rotary handle, and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning, depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 2.5 cm (width), 13 cm (height), 6 cm (Depth).
Specifications:
Range of product: EasyPact
Product or component type: Circuit breaker
Device short name: Easypact EZC100N
Device application: Distribution
Poles description: 1P
Protected poles description: 1t
Network type: AC, DC
Network frequency: 50/60 Hz
Rated current In: 25 A at 40 °C
Rated insulation voltage Ui: 690 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage Uimp: 6 kV conforming to IEC 60947-2
Rated operational voltage Ue: 125 V DC conforming to IEC 60947-2, 415 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code: N
Breaking capacity Icu: 25 kA at 110-130 V AC 50/60 Hz, 5 kA at 125 V DC 1P, 18 kA at 220-240 V AC 50/60 Hz, 2.5 kA at 380 V AC 50/60 Hz, 2.5 kA at 400-415 V AC 50/60 Hz (all conforming to IEC 60947-2)
Rated service breaking capacity Ics: 12.5 kA at 110/130 V AC 50/60 Hz, 2.5 kA at 125 V DC, 9 kA at 220/230/240 V AC 50/60 Hz, 1.25 kA at 380 V AC, 1.25 kA at 400/415 V AC (conforming to IEC 60947-2)
Suitability for isolation: Yes conforming to IEC 60947-2
Utilisation category: Category A
Trip unit name: TM-D
Trip unit technology: Thermal-magnetic
Trip unit rating: 25 A at 50 °C
Protection type: Overload protection, Short-circuit protection
Pollution degree: 3 conforming to IEC 60664-1 and 3 conforming to IEC 947-1
Main Features:
Control type: Toggle
Mounting mode: Fixed
Mounting support: Backplate
Upside connection: Front
Downside connection: Front
Mechanical durability: 13000 cycles
Connection pitch: 2.5 cm
Local signalling: Positive contact indication
Neutral protection setting: Without protection
Earth-leakage protection: Without
Height: 13 cm
Width: 2.5 cm
Depth: 6 cm
Complementary:
Standards: JIS C8201-2-2, EN/IEC 60947-2, GB/T 14048.2, EN/IEC 60947-1
IP degree of protection: IP20 conforming to IEC 60529
IK degree of protection: IK07 conforming to IEC 62262
Ambient air temperature for operation: -25…70 °C
Ambient air temperature for storage: -35…85 °C
Packaging:
Unit Type of Package 1: PCE
Number of Units in Package 1: 1
Package 1 Height: 3.2 cm
Package 1 Width: 9.5 cm
Package 1 Length: 14 cm
Package 1 Weight: 340 g
Unit Type of Package 2: S02
Number of Units in Package 2: 32
Package 2 Height: 15 cm
Package 2 Width: 30 cm
Package 2 Length: 40 cm
Package 2 Weight: 11.303 kg
Warranty: 18 months
Environmental Data: Total lifecycle Carbon footprint is 41 CO2 equivalent emissions, Packaging made with recycled cardboard of minimum 70% content. Compliant with EU RoHS Directive. Certified for operation in pollution degree III environment.