Description
EZC250H3200 Circuit Breaker
This is a 200 A circuit breaker for EasyPact EZC250H. It works below rated operational voltage (Ue) 550 V AC at 50/60 Hz or 250 V DC network. The ultimate breaking capacity (Icu) varies depending on network conditions, with rated service breaking capacity (Ics) equal to 50% of Icu if needed.
This version is a 3 poles frame with detection on all 3 poles, equipped with a TM-D thermal-magnetic trip unit for overload and short-circuit protection. Compliant with IEC 60947 standards and CE certified. Tested and certified by independent labs including KEMA, ASEFA, TUV, and third-party Tilva.
Certified for operation in pollution degree 3 environment per IEC 60947, suitable for extreme atmospheric conditions. Can be mounted vertically or horizontally in metal enclosures and features padlocking to enhance safety. Protection degree is IP40 with direct rotary handle and IP54 with extended rotary handle.
The series has slots for indication or voltage release auxiliaries positioning behind the front cover. Fixed dimensions: width 10.5 cm, height 16.5 cm, depth 6 cm.
Specifications:
Range of product: EasyPact
Device short name: Easypact EZC250H
Device application: Distribution
Poles description: 3P
Protected poles: 3t
Network type: AC and DC
Network frequency: 50/60 Hz
Rated current: 200 A at 40 °C
Rated insulation voltage: 690 V AC 50/60 Hz IEC 60947-2
Rated impulse withstand voltage: 6 kV IEC 60947-2
Rated operational voltage: 550 V AC 50/60 Hz and 250 V DC IEC 60947-2
Breaking capacity code: H
Breaking capacity: 10 kA Icu at 550 V AC, 25 kA Icu at 440 V AC, 30 kA Icu at 125 V DC 1P, 30 kA Icu at 250 V DC 2P, 36 kA Icu at 380 V AC, 36 kA Icu at 400-415 V AC, 85 kA Icu at 110-130 V AC, 85 kA Icu at 220-240 V AC
Rated service breaking capacity: varies with voltage and current, e.g. 5 kA at 550 V AC, 15 kA at 125 V DC, up to 42.5 kA at 220-240 V AC
Suitability for isolation: Yes
Utilization category: Category A
Trip unit technology: Thermal-magnetic (TM-D)
Trip unit rating: 200 A at 50 °C
Protection type: Overload and short-circuit protection
Pollution degree: 3 as per IEC 60664-1 and IEC 947-1
Main:
Control type: Toggle
Mounting mode: Fixed
Mounting support: Backplate
Connections: Front top and bottom
Mechanical durability: 10,000 cycles
Connection pitch: 3.5 cm
Local signalling: Positive contact indication
Neutral protection setting: Without protection
Earth-leakage protection: Without
Dimensions: Height 16.5 cm, Width 10.5 cm, Depth 6 cm.
Complementary: Standards EN/IEC 60947-1, GB/T 14048.2, EN/IEC 60947-2; IP20 protection degree; IK07 IK degree; Operating ambient temperature -25 to 70 °C; Storage temperature -35 to 85 °C.
Packaging: Single unit (PCE): 10.6 cm height, 11.6 cm width, 18.2 cm length, 1.562 kg weight; Package of 8 (S03): 30 cm × 30 cm × 40 cm, 13.623 kg; Package of 64 (P12): 50 cm × 80 cm × 120 cm, 120.984 kg.
Warranty: 18 months.