Product PSTX105-600-70 Softstarter
The softstarter PSTX105-600-70 has a rated maximum operational current of 105 A with an operating voltage span from 208…600 V AC. The rated control voltage is between 100…250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp.
It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in normally open (NO) state.
The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. It also features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.
Interaction is through a detachable full graphic display with IP66 and 4x outdoor rating. Communication methods include hardwire inputs Start/Stop/Reset of fault and three programmable digital inputs, built-in Fieldbus communication Modbus RTU with optional ANYBUS modules for protocols like Profinet, Profibus, Modbus TCP, Ethernet IP and more, or via an external adapter and Fieldbus plug.
This softstarter is suitable for medium to large-sized three-phase motors with nominal currents from 30 to 1250 A inline connection or 52 to 2160 A inside delta connection. Typical applications include pumps, fans, compressors, and conveyors.
Dimensions: Width: 15 cm, Height: 31.4 cm, Depth: 19.8 cm.
Weight: 4.7 kg.
Electrical Specifications: Rated operational voltage: 208 … 600 V AC. Control supply voltage: 100 … 250 V AC. Control circuit voltage: 24 V DC. Frequency: 50/60 Hz.
Rated operational power (inline connection): 30 kW at 230 V, 55 kW at 400 V, 75 kW at 500 V. Rated operational current inline connection: 105 A.
Rated operational power (inside delta connection): 55 kW at 230 V, 90 kW at 400 V, 110 kW at 500 V. Rated operational current inside delta connection: 181 A.
Functions include: Auto phase sequence detection, automatic restart, current limit and ramp, dual current limit, dynamic brake, electricity metering, electronic overload with time-to-cool, emergency mode, event log, full voltage start, jogging with slow speed forward and reverse, keypad password, kick start, limp mode if thyristor fault, motor heating, pre-start function, pump cleaning, real-time clock, sequence start, soft start/stop with torque or voltage ramp, stand still brake, start reverse via external contactors, thyristor runtime measurement, torque limit, voltage sags detection.
Protection functions: Bypass open protection, current imbalance and underload protection, dual overload, earth/ground fault protection, electronic overload (EOL), IO failure protection, fieldbus and HMI failure protection, locked rotor protection, start limits, over/under voltage, phase reversal, power factor underload, temperature sensor connection, long current limit and start time protection, user defined protection, voltage imbalance.
Signal indications: Ready to start/standby LED green, running LED green, protection LED yellow, fault LED red.
Communication protocols: Modbus-RTU, Modbus-TCP, Ethernet-IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, BACnet-MSTP.
Degree of protection: According to IEC 60529, IEC 60947-1, EN 60529 main terminals IP00.
Terminal type: Cable clamp with hole diameter 8.5 mm for main circuit and rigid 2.5 mm² for control and supply circuits.
Tightening torque: 8 N·m for main circuit.
Environmental operating range: Operation temperature -25 to +60 °C, storage -40 to +70 °C.