Description
AF26-40-00-13 Block Contactor
Product ID: 1SBL237201R1300
EAN: 3471523115231
Description: The AF26-40-00-13 is a 4 pole – 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 11 kW / 400 V AC (AC-3) and switching power circuits up to 45 A (AC-1) or 45 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Customs Tariff Code: 85364900
Dimensions: Width 4.5 cm, Depth 10.1 cm, Height 8.6 cm, Weight 0.36 kg
Main Contacts: 4 NO, 0 NC; Auxiliary Contacts: 0 NO, 0 NC; Poles: 4P
Standards: IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1
Rated Operational Voltages: Main Circuit 690 V, Control Circuit 50 / 60 Hz
Current Ratings: AC-1 up to 45 A (40 °C, 690 V), AC-3 up to 23.2 A (various voltages), DC-1 up to 45 A (110 V, 2 to 4 Poles in Series, 40 °C)
Operational Power AC-3: Up to 11 kW (400-500 V), 9 kW at 690 V
Short-time Withstand Current (Icw): 300 A (10 s, 40 °C), 450 A (1 s, 40 °C), 225 A (30 s, 40 °C)
Insulation and Impulse Withstand Voltages: 690 V IEC rated insulation voltage, 6 kV impulse withstand voltage
Switching Frequencies: Max electrical 600 cycles/hour (AC-1), Max mechanical 3600 cycles/hour
Control Circuit Voltage Range: 100 to 250 V AC 50/60 Hz and DC
Power Loss: 1.6 W (AC-1, per pole), 0.42 W (AC-3, per pole)
Operate Times: Between coil de-energization and NC contact closing 13-98 ms, coil energization and NO contact closing 40-95 ms, others in between
Mounting: On DIN rail TH35-15 or TH35-7.5, or by 2 diagonally placed M4 screws
Connecting Capacities: Main circuit flexible ferrule 1.5 to 16 mm², solid 1.5 to 4 mm²; Control circuit flexible ferrule 0.75 to 2.5 mm², solid 1 to 2.5 mm²
Wire Stripping Length: Control Circuit 1.0 cm, Main Circuit 1.2 cm
Degree of Protection: Coil and main terminals IP20 according to IEC 60529
Tightening Torques: Control circuit 1.2 N·m, main circuit 2.5 N·m
Terminal Type: Screw Terminals
UL/CSA Ratings: Max operating voltage 600 V, general use rating 45 A at 600 V AC
Operating Temperature: Storage -60 to 80 °C, Operation -40 to 70 °C
Climatic Withstand: Category B IEC 60947-1 Annex Q
Maximum Operating Altitude: 3000 m without derating
Resistance to Shock: Various directions and magnitudes up to 30 g in certain directions
Resistance to Vibrations: 4g closed position & 2g open position from 5 to 300 Hz
Pollution Degree: 3