الوصف
Contactor, high power, TeSys Giga, standard version, 3 pole/NO, AC-3 <=440V 225A, 100-250VAC/DC coil
SKU: LC1G225KUEN
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 225A 132kW@440V. It provides a 100-250V AC/DC wide band low consumption electronic coil and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 255mm x 108mm x 175mm (H x W x D), compact size enables panel space savings. Multi standards certified (CE,CB,CCC,cULus,EAC,KC,RCM,Marine). Unique QR code provides quick access to complete product data.
Specifications
Brand: Schneider Electric
Range: TeSys
Range of Product: TeSys Giga
Product or Component Type: Contactor
Device short name: LC1G
Contactor application: Power switching
Motor control
Utilisation category: AC-1
AC-3
AC-3e
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-8a
AC-8b
DC-1
DC-3
DC-5
Poles description: 3P
[Ue] rated operational voltage: <= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current: 225 A (at <140 °F (60 °C)) at <= 440 V AC-3
[Uc] control circuit voltage: 100…250 V AC 50/60 Hz
100…250 V DC
Control circuit voltage limits: Operational: 0.8 Uc Min…1.1 Uc Max (at <140 °F (60 °C))
Drop-out: 0.1 Uc Max…0.45 Uc Min (at <140 °F (60 °C))
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 330 A (at 104 °F (40 °C))
Rated breaking capacity: 2050 A at 440 V
[Icw] rated short-time withstand current: 1.8 kA – 10 s
1.0 kA – 30 s
0.85 kA – 1 min
0.56 kA – 3 min
0.44 kA – 10 min
Associated fuse rating: 250 A aM at <= 440 V for motor
200 A aM at <= 690 V for motor
400 A gG at <= 690 V
400 A UL Type J at <= 600 V
Average impedance: 0.00015 Ohm
[Ui] rated insulation voltage: 1000 V
Power dissipation per pole: 20 W AC-1 – Ith 330 A
8 W AC-3 – Ith 225 A
Compatibility code: LC1G
Pole contact composition: 3 NO
Auxiliary contact composition: 1 NO + 1 NC
Motor power kW: 55 kW at 230 V AC 50/60 Hz (AC-3e)
110 kW at 400 V AC 50/60 Hz (AC-3e)
110 kW at 415 V AC 50/60 Hz (AC-3e)
132 kW at 440 V AC 50/60 Hz (AC-3e)
132 kW at 500 V AC 50/60 Hz (AC-3e)
160 kW at 690 V AC 50/60 Hz (AC-3e)
132 kW at 1000 V AC 50/60 Hz (AC-3e)
55 kW at 230 V AC 50/60 Hz (AC-3)
110 kW at 400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
132 kW at 440 V AC 50/60 Hz (AC-3)
132 kW at 500 V AC 50/60 Hz (AC-3)
160 kW at 690 V AC 50/60 Hz (AC-3)
132 kW at 1000 V AC 50/60 Hz (AC-3)
55 kW at 230 V AC 50/60 Hz (AC-4)
110 kW at 400 V AC 50/60 Hz (AC-4)
110 kW at 415 V AC 50/60 Hz (AC-4)
129 kW at 440 V AC 50/60 Hz (AC-4)
132 kW at 500 V AC 50/60 Hz (AC-4)
132 kW at 690 V AC 50/60 Hz (AC-4)
110 kW at 1000 V AC 50/60 Hz (AC-4)
Maximum Horse Power Rating: 60 hp at 200/208 V 60 Hz
75 hp at 230/240 V 60 Hz
150 hp at 460/480 V 60 Hz
150 hp at 575/600 V 60 Hz
Irms rated making capacity: 2720 A at 440 V
Coil technology: Built-in bidirectional peak limiting
Safety reliability level: B10d = 400000 cycles contactor with nominal load EN/ISO 13849-1
B10d = 3000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability: 8 Mcycles
inrush power in VA (50/60 Hz, AC): 540 VA
inrush power in W (DC): 380 W
hold-in power consumption in VA (50/60 Hz, AC): 12.4 VA
hold-in power consumption in W (DC): 7.8 W
Operating time: 40…70 ms closing
15…50 ms opening
Maximum operating rate: 600 cyc/h AC-3
600 cyc/h AC-3e
300 cyc/h AC-1
150 cyc/h AC-4
Mounting Support: Plate
Standards: EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
JIS C8201-5-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-1
UL 60335-2-40:Annex JJ
Product Certifications: CB Scheme
CCC
cULus
EAC
CE
UKCA
EU-RO-MR by DNV-GL
Tightening torque: 159.3 lbf.in (18 N.m)
Height: 19.3 cm
Width: 10.8 cm
Depth: 19.3 cm
Net Weight: 3.5 kg
IP degree of protection: IP2X front face with shrouds IEC 60529
IP2X front face with shrouds VDE 0106
Ambient Air Temperature for Operation: -13…140 °F (-25…60 °C)
Ambient Air Temperature for Storage: -76…176 °F (-60…80 °C)
Mechanical robustness: Vibrations 5…300 Hz 2 gn contactor open
Vibrations 5…300 Hz 4 gn contactor closed
Shocks 10 gn 11 ms contactor open
Shocks 15 gn 11 ms contactor closed
color: Dark grey
Protective treatment: TH
Permissible ambient air temperature around the device: -40…158 °F (-40…70 °C) at Uc
GTIN: 3606481921956
Country of origin: CZ
Warranty: 18 months