الوصف
Description
LP1K1201BD is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 24V DC coil and 1NC auxiliary contact allowing easy integration to all control systems. LP1K1201BD is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 5.5kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it can be easily integrated into all control systems thanks to its 24V DC coil and 1NC built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine). Very compact, 45mm wide, for DIN-rail and panel mounting. Ready for connection to all control systems thanks to a 24V DC control voltage and 1NC built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
Main
Range: TeSys
Product or Component Type: Contactor
Device short name: LP1K
Contactor application: Resistive load
Motor control
Utilisation category: AC-3
AC-3e
AC-1
AC-4
Poles description: 3P
power pole contact composition: 3 NO
[Ue] rated operational voltage: Power circuit <= 690 V AC <= 400 Hz
Signalling circuit <= 690 V AC <= 400 Hz
[Ie] rated operational current: 12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
12 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit
20 A (at <140 °F (60 °C)) at <= 690 V AC AC-1 for power circuit
Control circuit type: DC standard
[Uc] control circuit voltage: 24 V DC
Motor power kW: 3 kW 220…230 V AC 50/60 Hz AC-3
5.5 kW 380…415 V AC 50/60 Hz AC-3
5.5 kW 440 V AC 50/60 Hz AC-3
4 kW 690 V AC 50/60 Hz AC-3
3 kW 220…230 V AC 50/60 Hz AC-3e
5.5 kW 380…415 V AC 50/60 Hz AC-3e
5.5 kW 440 V AC 50/60 Hz AC-3e
4 kW 690 V AC 50/60 Hz AC-3e
3 kW 220…230 V AC 50/60 Hz AC-4
5.5 kW 380…415 V AC 50/60 Hz AC-4
5.5 kW 440 V AC 50/60 Hz AC-4
Auxiliary contact composition: 1 NC
[Uimp] rated impulse withstand voltage: 8 kV
Overvoltage category: III
[Ith] conventional free air thermal current: 20 A (at 140 °F (60 °C)) for power circuit
10 A (at 122 °F (50 °C)) for signalling circuit
Irms rated making capacity: 144 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Rated breaking capacity: 110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
[Icw] rated short-time withstand current: 115 A 122 °F (50 °C) – 1 s for power circuit
105 A 122 °F (50 °C) – 5 s for power circuit
100 A 122 °F (50 °C) – 10 s for power circuit
75 A 122 °F (50 °C) – 30 s for power circuit
55 A 122 °F (50 °C) – 1 min for power circuit
50 A 122 °F (50 °C) – 3 min for power circuit
25 A 122 °F (50 °C) – >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating: 25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Average impedance: 3 mOhm – Ith 20 A 50 Hz for power circuit
[Ui] rated insulation voltage: Power circuit 600 V UL 508
Power circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-5-1
Signalling circuit 600 V UL 508
Power circuit 600 V CSA C22.2 No 14
Signalling circuit 600 V CSA C22.2 No 14
Insulation resistance: > 10 MOhm for signalling circuit
Inrush power in W: 3 W 68 °F (20 °C))
Hold-in power consumption in W: 3 W 68 °F (20 °C)
Heat dissipation: 1.3 W
Control circuit voltage limits: Operational: 0.8…1.15 Uc (at <122 °F (50 °C))
Drop-out: >= 0.10 Uc (at <122 °F (50 °C))
Connections – terminals: screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end
screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid
screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end
screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end
Power circuit screw clamp terminals 2 0.002 in² (1.5 mm²)flexible with cable end
Maximum operating rate: 3600 cyc/h
Coil technology: Without built-in suppressor module
Auxiliary contacts type: Instantaneous 1 NC
Minimum switching current: 5 mA for signalling circuit
Minimum switching voltage: 17 V for signalling circuit
Mounting Support: Rail
Plate
Tightening torque: 7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals Philips No 2
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals flat Ø 6 mm
7.08…11.5 lbf.in (0.8…1.3 N.m) screw clamp terminals pozidriv No 2
Operating time: 30…40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability: 10 Mcycles
Electrical durability: 1.3 Mcycles 12 A AC-3 <= 440 V
1.3 Mcycles 12 A AC-3e <= 440 V
0.3 Mcycles 20 A AC-1 <= 690 V
0.02 Mcycles 72 A AC-4 <= 440 V
Height: 58 mm
Width: 45 mm
Depth: 57 mm
Net Weight: 0.225 kg
Complementary
Standards: EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
Product Certifications: CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
IP degree of protection: IP2X
Ambient air temperature for operation: -13…122 °F (-25…50 °C)
Ambient Air Temperature for Storage: -58…176 °F (-50…80 °C)
Permissible ambient air temperature around the device: -40…158 °F (-40…70 °C) at Uc
Operating altitude: 6561.68 ft (2000 m) without derating
Flame retardance: V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Environment
GTIN: 3389110790771
Returnability: Yes
Country of origin: ID
Ordering and shipping details
Unit Type of Package 1: PCE
Nbr. of units in pkg.: 1
Package 1 Height: 6.600 cm
Package 1 Width: 4.800 cm
Package 1 Length: 6.200 cm
Package weight(Lbs): 7.760 oz (220.000 g)
Unit Type of Package 2: S02
Number of Units in Package 2: 40
Package 2 Height: 15.000 cm
Package 2 Width: 30.000 cm
Package 2 Length: 40.000 cm
Package 2 Weight: 9.220 kg
Contractual warranty
Warranty (in months): 18