IEC contactor, TeSys Deca, nonreversing, 80A, 60HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 48VAC 50/60Hz coil, open
TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 80A/1000V AC-3/AC-3e (37kW@400V). They can be used to create motor starters for almost any type of application. It provides a 48V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by screw terminals, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (85mm width), DIN-rail mounting or screw fixing. Contactor is rated for 25HP at 200 to 208VAC, 30HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 150A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 175A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 48 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 5.00 inches tall, 3.35 inches wide and 5.12 inches deep. It weighs 3.51 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.
Specifications
Range: TeSys
Range of Product: TeSys Deca
Product or Component Type: Contactor
Device short name: LC1D
Contactor application: Motor control
Resistive load
Utilisation category: AC-3
AC-3e
AC-4
AC-1
Poles description: 3P
[Ue] rated operational voltage: Power circuit <= 300 V DC 25…400 Hz
Power circuit <= 690 V AC
[Ie] rated operational current: 125 A (at <140 °F (60 °C)) at <= 1000 V AC AC-1 for power circuit
80 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit
80 A (at <140 °F (60 °C)) at <= 440 V AC-3e for power circuit
[Uc] control circuit voltage: 48 V AC 50/60 Hz
Main
Motor power kW: 22 kW at 220…230 V AC 50/60 Hz (AC-3)
37 kW at 380…400 V AC 50/60 Hz (AC-3)
45 kW at 415…440 V AC 50/60 Hz (AC-3)
55 kW at 500 V AC 50/60 Hz (AC-3)
45 kW at 660…690 V AC 50/60 Hz (AC-3)
15 kW at 400 V AC 50/60 Hz (AC-4)
22 kW at 220…230 V AC 50/60 Hz (AC-3e)
37 kW at 380…400 V AC 50/60 Hz (AC-3e)
45 kW at 415…440 V AC 50/60 Hz (AC-3e)
55 kW at 500 V AC 50/60 Hz (AC-3e)
45 kW at 660…690 V AC 50/60 Hz (AC-3e)
Maximum Horse Power Rating: 7.5 hp at 120 V AC 50/60 Hz for 1 phase motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
30 hp at 200/208 V AC 50/60 Hz for 3 phase motors
30 hp at 230/240 V AC 50/60 Hz for 3 phase motors
60 hp at 460/480 V AC 50/60 Hz for 3 phase motors
60 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Compatibility code: LC1D
Pole contact composition: 3 NO
Protective cover: With
[Ith] conventional free air thermal current: 10 A (at 140 °F (60 °C)) for signalling circuit
125 A (at 140 °F (60 °C)) for power circuit
Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1100 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity: 1100 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current: 640 A 104 °F (40 °C) – 10 s for power circuit
990 A 104 °F (40 °C) – 1 s for power circuit
135 A 104 °F (40 °C) – 10 min for power circuit
320 A 104 °F (40 °C) – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit
Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit
Average impedance: 0.8 mOhm – Ith 125 A 50 Hz for power circuit
Power dissipation per pole: 5.1 W AC-3
12.5 W AC-1
5.1 W AC-3e
[Ui] rated insulation voltage: Power circuit 600 V CSA
Power circuit 600 V UL
Power circuit 1000 V IEC 60947-4-1
Signalling circuit 690 V IEC 60947-1
Signalling circuit 600 V CSA
Signalling circuit 600 V UL
Overvoltage category: III
Pollution degree: 3
[Uimp] rated impulse withstand voltage: 8 kV IEC 60947
Safety reliability level: B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Mechanical durability: 4 Mcycles
Electrical durability: 0.8 Mcycles 125 A AC-1 <= 440 V
1.5 Mcycles 80 A AC-3 <= 440 V
1.5 Mcycles 80 A AC-3e <= 440 V
Control circuit type: AC 50/60 Hz standard
Coil technology: Without built-in suppressor module
Control circuit voltage limits: 0.85…1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 60 Hz
0.3…0.6 Uc (-40…158 °F (-40…70 °C)):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…131 °F (-40…55 °C)):operational AC 50 Hz
1…1.1 Uc (131…158 °F (55…70 °C)):operational AC 50/60 Hz
Inrush power in VA: 245 VA 60 Hz cos phi 0.75 (at 68 °F (20 °C))
245 VA 50 Hz cos phi 0.75 (at 68 °F (20 °C))
Hold-in power consumption in VA: 26 VA 60 Hz cos phi 0.3 (at 68 °F (20 °C))
26 VA 50 Hz cos phi 0.3 (at 68 °F (20 °C))
Heat dissipation: 6…10 W at 50/60 Hz
Operating time: 20…35 ms closing
6…20 ms opening
Maximum operating rate: 3600 cyc/h at 60 °C
Connections – terminals: Control circuit: screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²) – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Control circuit: screw clamp terminals 2 0.002…0.006 in² (1…4 mm²) – cable stiffness: solid without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: flexible without cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 2 0.006…0.02 in² (4…16 mm²) – cable stiffness: flexible with cable end
Power circuit: connector 1 0.006…0.08 in² (4…50 mm²) – cable stiffness: solid without cable end
Power circuit: connector 2 0.006…0.04 in² (4…25 mm²) – cable stiffness: solid without cable end
Tightening torque: Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2
Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm
Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)
Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2
Auxiliary contact composition: 1 NO + 1 NC
Auxiliary contacts type: Mechanically linked 1 NO + 1 NC IEC 60947-5-1
Mirror contact 1 NC IEC 60947-4-1
Signalling circuit frequency: 25…400 Hz
Minimum switching voltage: 17 V for signalling circuit
Minimum switching current: 5 mA for signalling circuit
Insulation resistance: > 10 MOhm for signalling circuit
Non-overlap time: 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
Mounting Support: Plate
Rail
Complementary
Standards: EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
CSA C22.2 No 14
UL 60947-4-1
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
IEC 60335-1:Clause 30.2
Product Certifications: CCC
UL
CB Scheme
CSA
CE
UKCA
Marine
EAC
IP degree of protection: IP20 front face IEC 60529
Protective treatment: THIEC 60068-2-30
Climatic withstand: IACS E10 exposure to damp heat
Permissible ambient air temperature around the device: -40…140 °F (-40…60 °C)
140…158 °F (60…70 °C) with derating
Operating altitude: 0…9842.52 ft (0…3000 m)
Fire resistance: 1562 °F (850 °C) IEC 60695-2-1
Flame retardance: V1 conforming to UL 94
Mechanical robustness: Vibrations contactor open 2 Gn, 5…300 Hz)
Shocks contactor open 8 Gn for 11 ms)
Vibrations contactor closed 3 Gn, 5…300 Hz)
Shocks contactor closed 10 Gn for 11 ms)
Height: 5 in (127 mm)
Width: 3.3 in (85 mm)
Depth: 5.1 in (130 mm)
Net Weight: 3.51 lb(US) (1.59 kg)
Environment
Category: US1CTR121252
Discount Schedule: CTR1
GTIN: 3389110440522
Returnability: No
Country of origin: CZ
Ordering and shipping details
Unit Type of Package 1: PCE
Nbr. of units in pkg.: 1
Package 1 Height: 6.299 in (16.000 cm)
Package 1 Width: 5.315 in (13.500 cm)
Package 1 Length: 3.740 in (9.500 cm)
Package weight(Lbs): 3.426 lb(US) (1.554 kg)
Unit Type of Package 2: S02
Number of Units in Package 2: 5
Package 2 Height: 5.9 in (15 cm)
Package 2 Width: 11.8 in (30 cm)
Package 2 Length: 15.7 in (40 cm)
Package 2 Weight: 17.824 lb(US) (8.085 kg)
Unit Type of Package 3: P06
Number of Units in Package 3: 80
Package 3 Height: 29.528 in (75.000 cm)
Package 3 Width: 23.622 in (60.000 cm)
Package 3 Length: 31.496 in (80.000 cm)
Package 3 Weight: 293.612 lb(US) (133.180 kg)
Packing Units
Warranty (in months): 18