Product PSTX170-600-70 Softstarter
The softstarter PSTX170-600-70 has a rated maximum operational current of 170 A with an operating voltage span from 208…600 V AC. The rated control voltage is between 100…250 V AC at 50/60 Hz. PSTX features a three-phase control soft start and stop through a voltage or a torque ramp.
It has built-in bypass for easy installation and energy saving. A RUN, TOR and Event signal is available from relay outputs in NO (normally open state). The PSTX has functions such as current limit, kickstart, analog output, EOL, motor heating and pump cleaning. PSTX also features jog, braking, stand-still brake, diagnostics, sequence start and emergency/fire pump mode as standard.
It has a detachable full graphic display with IP66 and 4x outdoor rating. There are four ways to communicate with PSTX: hardwire inputs Start/Stop/Reset of fault, three programmable digital inputs, built-in Fieldbus communication with Modbus RTU and optional ANYBUS modules including major protocols such as Profinet, Profibus, Modbus TCP, Ethernet IP and others, or an external adaptor and Fieldbus plug.
PSTX is the complete alternative for any motor starting application. It is suitable for medium to large-sized three-phase motors with nominal currents from 30 to 1250 A inline connection or 52 to 2160 A inside delta connection.
Typical applications include pumps, fans, compressors, and conveyors.
Rated Operational Voltage: 208 … 600 V AC
Rated Control Supply Voltage (Us): 100 … 250 V AC
Rated Control Circuit Voltage (Uc): 24 V DC
Rated Frequency: 50/60 Hz
Net Dimensions (WxHxD): 19.9 cm x 37.7 cm x 28.3 cm
Net Weight: 8.9 kg
Rated Operational Power – In-Line Connection: 45 kW at 230 V, 90 kW at 400 V, 110 kW at 500 V
Rated Operational Current – In-Line Connection: 170 A
Rated Operational Power – Inside Delta Connection: 90 kW at 230 V, 160 kW at 400 V, 200 kW at 500 V
Rated Operational Current – Inside Delta Connection: 300 A
Service Factor: 100 %
Overload Protection: Built-in electronic overload protection
Ramp Time: 1 to 120 seconds
Initial Voltage During Start: 10 to 99 %
Current Limit Function: 1.5 to 7.5 x Ie
Protection Functions Include: Bypass open protection, current imbalance protection, earth fault protection, electronic overload protection, locked rotor protection, over voltage protection, phase reversal protection, and more.
Communication Protocols: Modbus-RTU, Modbus-TCP, Ethernet-IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet-IP, BACnet-MSTP.