| الوزن |
2 كيلوجرام |
| الأبعاد |
15.0 × 10.7 × 14.3 سنتيميتر |
| Customs Tariff Code |
US1CP4D22157
|
| Device Short Name |
ATV212
|
| Product Destination |
Asynchronous motors
|
| Phase |
3
|
| Motor Power kW |
1.5
|
| Maximum Horse Power Rating |
2
|
| Supply Voltage Limits |
323…528 V
|
| Supply Frequency |
50…60 Hz – 5…5 %
|
| Line Current 480V |
2.5
|
| Line Current 380V |
3.2
|
| Range of Product |
Altivar 212
|
| Product or Component Type |
Variable speed drive
|
| Product Specific Application |
Pumps and fans in HVAC
|
| Communication Port Protocol |
APOGEE FLN, BACnet, Modbus, LonWorks, METASYS N2
|
| Us Rated Supply Voltage |
380…480 V – 15…10 %
|
| EMC Filter |
Class C2 EMC filter integrated
|
| Apparent Power |
2.8 kVA 380 V
|
| Continuous Output Current 380V |
3.7
|
| Continuous Output Current 460V |
3.7
|
| Maximum Transient Current |
4 A 60 s
|
| Speed Drive Output Frequency |
0.5…200 Hz
|
| Speed Range |
1…10
|
| Speed Accuracy |
+/- 10 % of nominal slip 0.2 Tn to Tn
|
| Local Signalling |
1 LED (red) for DC bus energized
|
| Output Voltage |
<= power supply voltage
|
| Isolation |
Electrical between power and control
|
| Type of Cable |
Without mounting kit 1 IEC cable 113 °F (45 °C), copper 90 °C / XLPE/EPR; Without mounting kit 1 IEC cable 113 °F (45 °C), copper 70 °C / PVC; With UL Type 1 kit 3 UL 508 cable 104 °F (40 °C), copper 75 °C / PVC
|
| Electrical Connection |
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5 mm² / AWG 14; L1/R, L2/S, L3/T terminal 6 mm² / AWG 10
|
| Tightening Torque VIA |
0.6 N.m
|
| Tightening Torque L1R L2S L3T |
1.3 N.m
|
| Supply |
Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection; Internal supply 24 V DC 21…27 V, <200 A overload and short-circuit protection
|
| Sampling Duration |
2 ms +/- 0.5 ms F discrete, 2 ms +/- 0.5 ms R discrete, 2 ms +/- 0.5 ms RES discrete, 3.5 ms +/- 0.5 ms VIA analog, 22 ms +/- 0.5 ms VIB analog
|
| Response Time |
FM 2 ms +/- 0.5 ms analog, FLA, FLC 7 ms +/- 0.5 ms discrete, FLB, FLC 7 ms +/- 0.5 ms discrete, RY, RC 7 ms +/- 0.5 ms discrete
|
| Accuracy VIA VIB FM |
+/- 0.6 % VIA and VIB for a temperature variation 60 °C; +/- 1 % FM for a temperature variation 60 °C
|
| Linearity Error |
VIA +/- 0.15 % of maximum value input; VIB +/- 0.15 % of maximum value input; FM +/- 0.2 % output
|
| Analogue Output Type |
FM switch-configurable voltage 0…10 V DC 7620 Ohm 10 bits; FM switch-configurable current 0…20 mA 970 Ohm 10 bits
|
| Discrete Output Type |
Configurable relay logic FLA, FLC) NO – 100000 cycles; Configurable relay logic FLB, FLC) NC – 100000 cycles; Configurable relay logic RY, RC) NO – 100000 cycles
|
| Minimum Switching Current |
3 mA 24 V DC configurable relay logic
|
| Maximum Switching Current |
5 A 250 V AC resistive cos phi = 1 L/R = 0 ms FL, R; 5 A 30 V DC resistive cos phi = 1 L/R = 0 ms FL, R; 2 A 250 V AC inductive cos phi = 0.4 L/R = 7 ms FL, R; 2 A 30 V DC inductive cos phi = 0.4 L/R = 7 ms FL, R
|
| Discrete Input Type |
F programmable 24 V DC level 1 PLC 4700 Ohm; R programmable 24 V DC level 1 PLC 4700 Ohm; RES programmable 24 V DC level 1 PLC 4700 Ohm
|
| Discrete Input Logic |
Positive logic (source) F, R, RES), <= 5 V, >= 11 V; Negative logic (sink) F, R, RES), >= 16 V, <= 10 V
|
| Dielectric Strength |
3535 V DC between earth and power terminals; 5092 V DC between control and power terminals
|
| Insulation Resistance |
>= 1 mOhm 500 V DC for 1 minute
|
| Frequency Resolution |
Display unit 0.1 Hz; Analog input 0.024/50 Hz
|
| Communication Service |
Read device identification (43); Time out setting from 0.1 to 100 s; Monitoring inhibitable; Write single register (06); Read holding registers (03) 2 words maximum; Write multiple registers (16) 2 words maximum
|
| Option Card |
Communication card LonWorks
|
| Power Dissipation W |
78
|
| Air Flow Gal hr US |
7132.8
|
| Functionality |
Mid
|
| Specific Application |
HVAC
|
| Variable Speed Drive Application Selection |
Building – HVAC compressor for scroll, Building – HVAC fan, Building – HVAC pump
|
| Motor Power Range AC 3 |
1.1…2 kW 380…440 V 3 phase; 1.1…2 kW 480…500 V 3 phase
|
| Motor Starter Type |
Variable speed drive
|
| Discrete Output Number |
2
|
| Analogue Input Number |
2
|
| Analogue Input Type |
VIA switch-configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits; VIB configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits; VIB configurable PTC probe 0…6 probes 1500 Ohm; VIA switch-configurable current 0…20 mA 250 Ohm 10 bits
|
| Analogue Output Number |
1
|
| Physical Interface |
2-wire RS 485
|
| Connector Type |
1 open style, 1 RJ45
|
| Transmission Rate |
9600 bps or 19200 bps
|
| Transmission Frame |
RTU
|
| Number of Addresses |
1…247
|
| Data Format |
8 bits, 1 stop, odd even or no configurable parity
|
| Type of Polarization |
No impedance
|
| Asynchronous Motor Control Profile |
Voltage/frequency ratio – Energy Saving, quadratic U/f; Voltage/frequency ratio, 5 points; Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo); Voltage/frequency ratio, 2 points; Flux vector control without sensor, standard
|
| Torque Accuracy |
+/- 15 %
|
| Transient Overtorque |
120 % of nominal motor torque +/- 10 % 60 s
|
| Acceleration and Deceleration Ramps |
Linear adjustable separately from 0.01 to 3200 s; Automatic based on the load
|
| Motor Slip Compensation |
Adjustable; Not available in voltage/frequency ratio motor control; Automatic whatever the load
|
| Switching Frequency |
6…16 kHz adjustable; 12…16 kHz with derating factor
|
| Nominal Switching Frequency |
12 kHz
|
| Braking to Standstill |
By DC injection
|
| Network Frequency |
47.5…63 Hz
|
| Prospective Line Isc |
5 kA
|
| Protection Type |
Overheating protection drive; Thermal power stage drive; Short-circuit between motor phases drive; Input phase breaks drive; Overcurrent between output phases and earth drive; Overvoltages on the DC bus drive; Break on the control circuit drive; Against exceeding limit speed drive; Line supply overvoltage and undervoltage drive; Line supply undervoltage drive; Against input phase loss drive; Thermal protection motor; Motor phase break motor; With PTC probes motor
|
| Pollution Degree |
2 IEC 61800-5-1
|
| IP Degree of Protection |
IP21
|
| IP Degree of Protection Complementary |
IP20 on upper part without blanking plate on cover IEC 61800-5-1; IP20 on upper part without blanking plate on cover IEC 60529; IP21 IEC 61800-5-1; IP21 IEC 60529; IP41 on upper part IEC 61800-5-1; IP41 on upper part IEC 60529
|
| Vibration Resistance |
1.5 mm (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8
|
| Shock Resistance |
15 gn 11 ms IEC 60068-2-27
|
| Environmental Characteristic |
Classes 3C1 conforming to IEC 60721-3-3; Classes 3S2 conforming to IEC 60721-3-3
|
| Noise Level |
51 dB 86/188/EEC
|
| Operating Altitude ft |
3280.84…9842.52 ft limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m; <= 3280.84 ft (1000 m) without derating
|
| Relative Humidity |
5…95 % without condensation IEC 60068-2-3; 5…95 % without dripping water IEC 60068-2-3
|
| Ambient Air Temperature for Operation F |
14…104 °F (-10…40 °C) (without derating); 104…122 °F (40…50 °C) (with derating factor)
|
| Operating Position |
Vertical +/- 10 degree
|
| Product Certifications |
UL; NOM 117; C-tick; CSA
|
| Marking |
CE
|
| Standards |
EN 55011 class A group 1; IEC 61800-3 environments 2 category C1; EN 61800-3 category C3; IEC 61800-3; IEC 61800-3 environments 2 category C2; IEC 61800-3 environments 2 category C1; IEC 61800-3 environments 1 category C3; UL Type 1; IEC 61800-3 environments 2 category C3; IEC 61800-3 environments 1 category C2; IEC 61800-3 environments 1 category C3; IEC 61800-3; IEC 61800-3 environments 1 category C2; IEC 61800-3 environments 2 category C3; IEC 61800-3 environments 1 category C1; IEC 61800-5-1; IEC 61800-3 category C3; IEC 61800-3 category C2; IEC 61800-5-1; IEC 61800-3 category C2; IEC 61800-3 environments 1 category C1; IEC 61800-3 environments 2 category C2
|
| Assembly Style |
With heat sink
|
| Electromagnetic Compatibility |
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
|
| Regulation Loop |
Adjustable PI regulator
|
| Ambient Air Temperature for Storage F |
-13…158 °F (-25…70 °C)
|
| Category |
US1CP4D22157
|
| Discount Schedule |
CP4D
|
| Returnability |
Yes
|
| Country of Origin |
ID
|
| Unit Type of Package 1 |
PCE
|
| Nbr of Units in Pkg 1 |
1
|
| Package 1 Height cm |
17.5
|
| Package 1 Width cm |
17.3
|
| Package 1 Length cm |
20.5
|
| Package Weight Lbs |
4.359
|
| Package Weight kg |
1.977
|
| Unit Type of Package 2 |
S06
|
| Number of Units in Package 2 |
27
|
| Package 2 Height cm |
75
|
| Package 2 Width cm |
60
|
| Package 2 Length cm |
80
|
| Package 2 Weight Lbs |
143.722
|
| Package 2 Weight kg |
65.191
|
| Warranty |
18 months
|