| الوزن |
3.35 كيلوجرام |
| الأبعاد |
15.0 × 14.2 × 18.4 سنتيميتر |
| Product ID |
ATV212HU55N4
|
| Product Destination |
Asynchronous motors
|
| Phase |
3
|
| Motor Power kW |
5.5
|
| Max Horse Power Rating hp |
7.5
|
| Supply Voltage Limits V |
323…528
|
| Supply Frequency Hz |
50…60
|
| Line Current A |
10.9 at 380 V, 8.6 at 480 V
|
| Range of Product |
Altivar 212
|
| Product or Component Type |
Variable speed drive
|
| Product Specific Application |
Pumps and fans in HVAC
|
| Communication Port Protocol |
METASYS N2, LonWorks, BACnet, Modbus, APOGEE FLN
|
| Us Rated Supply Voltage V |
380…480
|
| EMC Filter |
Class C2 EMC filter integrated
|
| IP Degree of Protection |
IP21
|
| Apparent Power kVA |
9.1 at 380 V
|
| Continuous Output Current A |
12 at 380 V, 12 at 460 V
|
| Max Transient Current A |
13.2 for 60 s
|
| Speed Drive Output Frequency Hz |
0.5…200
|
| Speed Range |
1…10
|
| Speed Accuracy |
\+/\- 10 % of nominal slip 0.2 Tn to Tn
|
| Local Signalling |
1 LED (red) for DC bus energized
|
| Output Voltage |
<= power supply voltage
|
| Isolation |
Electrical between power and control
|
| Type of Cable |
Without mounting kit 1 IEC cable 45°C, copper 90°C / XLPE/EPR; Without mounting kit 1 IEC cable 45°C, copper 70°C / PVC; With UL Type 1 kit 3 UL 508 cable 40°C, copper 75°C / PVC
|
| Electrical Connection |
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal AWG14; L1/R, L2/S, L3/T terminal AWG10
|
| Tightening Torque Nm |
1.3 (L1/R, L2/S, L3/T), 0.6 (others)
|
| Supply |
Internal supply for reference potentiometer 10.5 V DC +/- 5%, <10 A overload and short-circuit protection; Internal supply 24 V DC (21–27 V), <200 A overload and short-circuit protection
|
| Sampling Duration ms |
2 +/- 0.5 discrete (F,R,RES), 3.5 +/- 0.5 analog (VIA), 22 +/- 0.5 analog (VIB)
|
| Response Time ms |
FM 2 +/- 0.5 analog; FLA, FLC 7 +/- 0.5 discrete; FLB, FLC 7 +/- 0.5 discrete; RY, RC 7 +/- 0.5 discrete
|
| Accuracy |
\+/\- 0.6% (VIA, VIB) for 60°C temperature variation; \+/\- 1% (FM) for 60°C temperature variation
|
| Linearity Error |
VIA +/- 0.15% of max value input; VIB +/- 0.15%; FM +/- 0.2% output
|
| Analogue Output Type |
FM switch-configurable voltage 0…10 V DC 7620 Ohm 10 bits; FM switch-configurable current 0…20 mA 970 Ohm 10 bits
|
| Discrete Output Type |
Configurable relay logic FLA, FLC NO – 100000 cycles; FLB, FLC NC – 100000 cycles; RY, RC NO – 100000 cycles
|
| Min Switching Current mA |
3 at 24 V DC configurable relay logic
|
| Max Switching Current A |
5 at 250 V AC resistive; 5 at 30 V DC resistive; 2 at 250 V AC inductive; 2 at 30 V DC inductive
|
| Discrete Input Type |
F, R, RES programmable 24 V DC level 1 PLC 4700 Ohm
|
| Discrete Input Logic |
Positive logic (source) (F, R, RES), <= 5 V, >= 11 V; Negative logic (sink) (F, R, RES), >= 16 V, <= 10 V
|
| Dielectric Strength VDC |
3535 between earth and power terminals; 5092 between control and power terminals
|
| Insulation Resistance mOhm |
>= 1 at 500 V DC for 1 minute
|
| Frequency Resolution Hz |
0.1 display unit; 0.024/50 analog input
|
| Communication Service |
Read device identification (43); Read holding registers (03) 2 words max; Write multiple registers (16) 2 words max; Write single register (06); Monitoring inhibitable; Time out setting 0.1 to 100 s
|
| Option Card |
Communication card LonWorks
|
| Power Dissipation W |
215
|
| Air Flow m3h |
74
|
| Functionality |
Mid
|
| Specific Application |
HVAC
|
| Variable Speed Drive Application Selection |
Building HVAC compressor for scroll; Building HVAC fan; Building HVAC pump
|
| Motor Power Range kW |
4…6
|
| Motor Starter Type |
Variable speed drive
|
| Discrete Output Number |
2
|
| Analogue Input Number |
2
|
| Analogue Input Type |
VIA switch-configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits; VIB configurable voltage 0…10 V DC 24 V max 30000 Ohm 10 bits; VIB configurable PTC probe 0…6 probes 1500 Ohm; VIA switch-configurable current 0…20 mA 250 Ohm 10 bits
|
| Analogue Output Number |
1
|
| Physical Interface |
2-wire RS 485
|
| Connector Type |
1 RJ45; 1 open style
|
| Transmission Rate bps |
9600 or 19200
|
| Transmission Frame |
RTU
|
| Number of Addresses |
1…247
|
| Data Format |
8 bits, 1 stop, odd even or no configurable parity
|
| Type of Polarization |
No impedance
|
| Asynchronous Motor Control Profile |
Voltage/frequency ratio 2 points; Voltage/frequency ratio 5 points; Voltage/frequency ratio automatic IR compensation (U/f + automatic Uo); Flux vector control without sensor standard; Voltage/frequency ratio Energy Saving quadratic U/f
|
| Torque Accuracy |
\+/\- 15 %
|
| Transient Overtorque |
120 % of nominal motor torque +/- 10 % 60 s
|
| Acceleration and Deceleration Ramps |
Automatic based on load; Linear adjustable separately 0.01 to 3200 s
|
| Motor Slip Compensation |
Not available in voltage/frequency ratio motor control; Automatic whatever the load; Adjustable
|
| Switching Frequency kHz |
6…16 adjustable; 12…16 with derating factor
|
| Nominal Switching Frequency kHz |
12
|
| Braking to Standstill |
By DC injection
|
| Network Frequency Hz |
47.5…63
|
| Prospective Line Isc kA |
22
|
| Protection Type |
Overheating protection drive; Thermal power stage drive; Short-circuit between motor phases drive; Input phase breaks drive; Overcurrent output phases and earth drive; Overvoltages on DC bus drive; Break on control circuit drive; Against exceeding limit speed drive; Line supply overvoltage/undervoltage drive; Against input phase loss drive; Thermal protection motor; Motor phase break motor; With PTC probes motor
|
| Pollution Degree |
3 IEC 61800-5-1
|
| IP Degree of Protection Complementary |
IP20 upper part without blanking plate IEC 61800-5-1/IEC 60529; IP21 IEC 61800-5-1/IEC 60529; IP41 upper part IEC 61800-5-1/IEC 60529
|
| Vibration Resistance |
1.5 mm (f=3…13 Hz) IEC 60068-2-6; 1 gn (f=13…200 Hz) EN/IEC 60068-2-8
|
| Shock Resistance |
15 gn 11 ms IEC 60068-2-27
|
| Environmental Characteristic |
Classes 3C1 and 3S2 IEC 60721-3-3
|
| Noise Level dB |
51
|
| Operating Altitude ft |
3281 to 9843 ft (1000 to 3000 m); limited to 2000 m for Corner Grounded distribution network with 1% derating per 100 m; <= 3281 ft (1000 m) without derating
|
| Relative Humidity |
5…95 % without condensation IEC 60068-2-3; 5…95 % without dripping water IEC 60068-2-3
|
| Ambient Air Temperature Operation |
-10…40 °C without derating; 40…50 °C with derating factor
|
| Operating Position |
Vertical +/- 10 degree
|
| Product Certifications |
NOM 117; CSA; C-tick; UL
|
| Marking |
CE
|
| Standards |
IEC 61800-3 category C3; IEC 61800-3 category C2; EN 61800-3 category C3; EN 55011 class A group 1; IEC 61800-3 environments 1 category C2; IEC 61800-3 environments 1 category C3; IEC 61800-3 environments 2 category C1; IEC 61800-3 environments 2 category C3; IEC 61800-5-1; UL Type 1
|
| Assembly Style |
With heat sink
|
| Electromagnetic Compatibility |
Electrostatic discharge immunity level 3 IEC 61000-4-2; Radiated RF immunity level 3 IEC 61000-4-3; Electrical fast transient/burst immunity level 4 IEC 61000-4-4; Surge immunity level 3 IEC 61000-4-5; Conducted RF immunity level 3 IEC 61000-4-6; Voltage dips and interruptions immunity IEC 61000-4-11
|
| Regulation Loop |
Adjustable PI regulator
|
| Ambient Air Temperature Storage |
-25…70 °C
|
| Category |
US1CP4D22157
|
| Discount Schedule |
CP4D
|
| Returnability |
Yes
|
| Unit Type of Package 1 |
PCE
|
| Nbr of Units in Pkg 1 |
1
|
| Package 1 Height cm |
27.0
|
| Package 1 Width cm |
26.0
|
| Package 1 Length cm |
26.0
|
| Package 1 Weight kg |
3.069
|
| Unit Type of Package 2 |
P06
|
| Nbr of Units in Pkg 2 |
12
|
| Package 2 Height cm |
75.0
|
| Package 2 Width cm |
60.0
|
| Package 2 Length cm |
80.0
|
| Package 2 Weight kg |
49.432
|
| Warranty Months |
18
|
| Customs Tariff Code |
85044090
|