الوصف
Technical characteristics
Architecture
- Fixing modeDin-Rail
Functions
- Number of function channels1
- FunctionKeylock by means of blocking key
Configuration
- Switch modechange-over contact
- Number of modules2
Controls and indicators
- Function of the pushbuttonyes
- Indication / displayLC display with illumination
Main electrical features
- Frequency50/60
Voltage
- Operating voltage230 V~ +/- 15%
Electric current
- Acceptable current rating with AC116 A
- Max. power with cos phi 0.610 A
- Switching current at cos φ = 0.6max. 10 A
Dimensions
- Depth of installed product65 mm
- Height of installed product85 mm
- Length35 mm
- Width of installed product65 mm
- Width of rail mounted device (RMD)2 modules
Frequency
- Frequency range50…60 Hz
Power
- Max. power with fluo uncompensated lamps1000 VA
- Power consumed6 VA
- Incandescent bulb power0 / 2300 W
- Total power loss under IN2 W
- Loss power at full load≈ 2 W
- Power dissipation per coil0.3 W
- Max. Breaking capacity for parallel compensated fluorescent tubes400 W
- Max. Breaking capacity for row-compensated fluorescent tubes1000 W
Measurement
- Running accuracy± 1.5 s/day
Battery
- Power reserve [years]≈ 5 a
- Battery / storage batterywith lithium battery type: LS14250
Power supply
- Supply voltage230 V +/- 15%
Fluorescent bulbs control
- Fluorescent lampsmax. 1000 VA
- Max. power with fluorescent parallel lamps400 VA
- Max. power fluo. duo lamp comp. series1000 W
- Fluorescent lamps parallel compensated400 VA
Incandescent bulbs control
- Max. power with incandescent lamps2300 W
- 230 V incandescent lamps and halogen lampsmax. 2300 W
Installation, mounting
- Mounting typedin-Rail
- Installation modefor mounting on DIN rail
Connection
- Connection cross-sect. flexible conductor1 / 6mm²
- Connection cross-sect. rigid cable1,5 / 10mm²
- Conductor cross-section (flexible)1…6 mm²
- Conductor cross-section (rigid)1…6 mm²
- Number of contacts1
- Type of contacts1 changeover contact floating
- Type of connectionwith screw terminals
Settings
- Number of program steps56
- Summer / Winter time changeautomatic
- Shortest switching time1 mn
- ProgrammingProgramming possible without mains voltage
- Astro programYes
- Timewith automatic summer/winter time change-over
Equipment
- Number of channels1
- Number of switching times for on/off56
- ON / OFF override0
- Supply failure reserve5 years
- With cyclic programYes
- With holidays programNo
- With random programNo
Use
- Cycleweekly
Safety
- Protection index IPIP20
- Keywith programming key
Use conditions
- Operating temperature-10…55 °C
- Working accuracy1,5
- Storage/transport temperature-20…60 °C
Identification
- Search wordsTimer;Digital time switch;Location-dependent;Energy-efficient;Lighting suited to requirements;Ideal lighting;Lighting control;Lighting control;