Description
XT2H 160 TMA 160-1600 3p F F
Extended Product Type: XT2H 160 TMA 160-1600 3p F F
Product ID: 1SDA067604R1
Brand: ABB
Manufacturer: ABB
Catalog Description: XT2H 160 TMA 160-1600 3p F F
Long Description: C.BREAKER TMAX XT2H 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 160 I3=800…1600 A
ABB EcoSolutions: Yes
ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
Recyclability Rate acc. to EN45555: 55.70 %
Order Code US and Canada: XT2HE3160BFF000XXX
E-Number (Finland): 3638054
E-Number (Norway): 4379301
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85362090
Dimensions (Width x Height x Depth): 9 cm x 13 cm x 8.25 cm
Net Weight: 1.4 kg
Package Level 1 Units: box 1 piece
Package Level 1 Dimensions (Width x Height x Depth): 13 cm x 20.8 cm x 14.5 cm
Package Level 1 Gross Weight: 1.659 kg
Circuit Breaker Type to be Associated: Power Distribution
Product Main Type: SACE Tmax XT
Product Name: Moulded Case Circuit Breaker
Product Type: Automatic Circuit Breaker
Version: F
Connecting Capacity Main Circuit: Busbar 32.5..100 mm²
Current Type: AC/DC
Electrical Durability: 8000 cycle
Mechanical Durability: 25000 cycle
Number of Poles: 3
Opening Time: CB with SOR 30 ms
Order Multiple: 1 piece
Power Loss per Pole: 16.15 W
Rated Current (In): 160 A
Rated Frequency: 50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp): 8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii): 800 to 1600 A
Rated Insulation Voltage (Ui): 1000 V
Rated Operational Voltage: 690 V AC / 500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics) AC (kA): (220 V AC) 100, (230 V AC) 100, (240 V AC) 100, (380 V AC) 70, (415 V AC) 70, (440 V AC) 65, (500 V AC) 50, (525 V AC) 30, (690 V AC) 15
Rated Service Short-Circuit Breaking Capacity (Ics) DC (kA): (250 V DC) 2 Poles in Series 70, (500 V DC) 3 Poles in Series 70
Rated Ultimate Short-Circuit Breaking Capacity (Icu) AC (kA): (220 V AC) 100, (230 V AC) 100, (240 V AC) 100, (380 V AC) 70, (415 V AC) 70, (440 V AC) 65, (500 V AC) 50, (525 V AC) 30, (690 V AC) 15
Rated Ultimate Short-Circuit Breaking Capacity (Icu) DC (kA): (250 V DC) 2 Poles in Series 70, (500 V DC) 3 Poles in Series 70
Rated Uninterrupted Current (Iu): 160 A
Rated Voltage (Ur): 690 V
Recommended Screw Driver: Main Circuit M6
Release: TMA
Release Type: TM
Setting Range: 112 to 160 A
Short-Circuit Performance Level: H
Standards: IEC60947-2
Sub-type: XT2
Terminal Connection Type: Front
Terminal Type: Bolt
Tightening Torque: 6 N·m
Certifications: No certification needed (ATEX, UL, VDE), GL Certificate: 1SDL000163R0093, LR Certificate: LRs certificate Tmax XT