الوصف
AX80-30-00-80 Block Contactor
Extended Product Type: AX80-30-00-80
Product ID: 1SBL411074R8000
EAN: 3471522407801
Description: AX50…AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Dimensions: Width 7 cm, Depth 11 cm, Height 10.8 cm
Weight: 1.01 kg
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Rated Operational Voltage: Auxiliary Circuit and Main Circuit 690 V
Rated Frequency: 50 / 60 Hz
Conventional Free-air Thermal Current (Ith): 125 A (IEC 60947-4-1 Θ = 40 °C)
Rated Operational Current AC-1 (Ie): 105 A at 220 / 240 V 55 °C, 125 A at 690 V 40 °C, 85 A at 690 V 70 °C
Rated Operational Current AC-3 (Ie): 80 A at 415 V 55 °C, 70 A at 440 V 55 °C, 65 A at 500 V 55 °C, 46 A at 690 V 55 °C, 80 A at 380 / 400 V 55 °C, 80 A at 220 / 230 / 240 V 55 °C
Rated Operational Power AC-3 (Pe): 40 kW at 415 V and 440 V, 45 kW at 500 V, 40 kW at 690 V, 37 kW at 380 / 400 V, 22 kW at 220 / 230 / 240 V
Rated Short-time Withstand Current Icw: 650 A (10 s), 135 A (15 min), 250 A (1 min), 1000 A (1 s), 370 A (30 s) at 40 °C ambient temperature in free air from cold state
Maximum Breaking Capacity: 1300 A at 440 V, 630 A at 690 V (cos phi=0.45, or 0.35 for Ie > 100 A)
Rated Insulation Voltage (Ui): 690 V (IEC 60947-4-1 and VDE 0110 Gr. C)
Rated Impulse Withstand Voltage (Uimp): 6 kV (Auxiliary Circuit)
Maximum Electrical Switching Frequency: 600 cycles per hour (AC-1 and AC-3)
Maximum Mechanical Switching Frequency: 3600 cycles per hour
Rated Control Circuit Voltage (Uc): 220 … 230 V at 50 Hz, 230 … 240 V at 60 Hz
Power Loss: 7 W at AC-1 and 2 W at AC-3 per pole
Operate Time: Between coil de-energization and NC contact closing 7 … 14 ms, NO contact opening 4 … 11 ms, coil energization and NC contact opening 7 … 22 ms, NO contact closing 8 … 27 ms
Degree of Protection: Coil terminals IP20, Main terminals IP10 (IEC 60529, IEC 60947-1, EN 60529)
Tightening Torque: Control circuit 1 N·m, Main circuit 4 N·m
Terminal Type: Screw terminals
UL/CSA Ratings: General use rating 105 A at 600 V AC; Horsepower rating varies from 7-1/2 hp Single Phase 120 V AC to 75 hp Three Phase 550 … 600 V AC
Tightening Torque UL/CSA: Auxiliary and control circuits 9 in·lb, main circuit 35 in·lb
Full Load Amps Motor Use: Ranges from 68 A Single Phase 240 V AC to 80 A Three Phase 220 … 240 V AC
Environmental Conditions: Ambient air temperature close to contactor fitted with thermal overload relay -25 … 55 °C, without relay -40 … 70 °C; storage -60 … 80 °C; operation in free air -40 … 70 °C; Climatic withstand according to IEC 60068-2-30 and 60068-2-11 – UTE C 63-100 Specification II
Maximum Operating Altitude: 3000 m without derating
Package Dimensions: Width 10.2 cm, Depth 14.3 cm, Height 15.2 cm; Gross Weight 1.12 kg
Customs Tariff Code: 85364900