| الوزن | 0.12 كيلوجرام |
|---|
| الأبعاد | 6.9 × 1.75 × 8.8 سنتيميتر |
|---|
| Product ID | 2CDS251001R0324 |
|---|
| Product Type | Miniature Circuit Breaker – S200 – 1P – 32 A – C – (AC) 6 kA |
|---|
| Catalog Description | Miniature Circuit Breaker – S200 – 1P – 32 A – C – (AC) 6 kA |
|---|
| Long Description | System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space. |
|---|
| Technical Information | {
"Dielectric_Test_Voltage_Attribute": "50 / 60 Hz – 1 min 2 kV",
"Rated_Ultimate_Short-Circuit_Breaking_Capacity_Icu_Attribute": {
"133_V_AC_Attribute": 20,
"230_V_AC_Attribute": 10,
"24_V_DC_Attribute": 20,
"60_V_DC_Attribute": 10,
"230_V_Attribute": 10,
"400_V_Attribute": 10
},
"Rated_Service_Short-Circuit_Breaking_Capacity_Ics_Attribute": {
"133_V_AC_Attribute": 15,
"230_V_AC_Attribute": 7.5
},
"Power_Supply_Connection_Attribute": "Arbitrary",
"Contact_Position_Indication_Attribute": "Red ON / Green OFF",
"Energy_Limiting_Class_Attribute": 3,
"Electrical_Endurance_Attribute": 10000,
"Mechanical_Endurance_Attribute": 20000,
"Number_of_Protected_Poles_Attribute": 1,
"Number_of_Poles_Attribute": "1P",
"Tightening_Torque_Nm_Attribute": 2.8,
"Actuator_Type_Attribute": "Toggle",
"Screw_Terminal_Type_Attribute": "Failsafe Bi-directional Cylinder-lift Terminal",
"Actuator_Marking_Attribute": "I / O",
"Actuator_Material_Attribute": "Insulation Group II, Black, Sealable",
"Recommended_Screw_Driver_Attribute": "Pozidriv 2",
"Accessories_Available_Attribute": "Yes",
"Connecting_Capacity_Attribute": {
"Busbar_Attribute": "10/10 mm²",
"Flexible_with_Ferrule_Attribute": "0.75 … 25 mm²",
"Flexible_Attribute": "0.75 … 25 mm²",
"Rigid_Attribute": "0.75 … 35 mm²",
"Stranded_Attribute": "0.75 … 35 mm²"
},
"Installation_Size_Attribute": "acc. to DIN 43880 1",
"Wire_Stripping_Length_mm_Attribute": 1.25,
"Terminal_Type_Attribute": "Screw Terminals"
} |
|---|
| Dielectric Test Voltage | 50 / 60 Hz – 1 min 2 kV |
|---|
| Rated Ultimate Short-Circuit Breaking Capacity Icu | {
"133_V_AC_Attribute": 20,
"230_V_AC_Attribute": 10,
"24_V_DC_Attribute": 20,
"60_V_DC_Attribute": 10,
"230_V_Attribute": 10,
"400_V_Attribute": 10
} |
|---|
| 133 V AC | 15 |
|---|
| 230 V AC | 7.5 |
|---|
| 24 V DC | 20 |
|---|
| 60 V DC | 10 |
|---|
| 230 V | 10 |
|---|
| 400 V | 10 |
|---|
| Rated Service Short-Circuit Breaking Capacity Ics | {
"133_V_AC_Attribute": 15,
"230_V_AC_Attribute": 7.5
} |
|---|
| Power Supply Connection | Arbitrary |
|---|
| Contact Position Indication | Red ON / Green OFF |
|---|
| Energy Limiting Class | 3 |
|---|
| Electrical Endurance | 10000 |
|---|
| Mechanical Endurance | 20000 |
|---|
| Number of Protected Poles | 1 |
|---|
| Number of Poles | 1P |
|---|
| Tightening Torque Nm | 2.8 |
|---|
| Actuator Type | Toggle |
|---|
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
|---|
| Actuator Marking | I / O |
|---|
| Actuator Material | Insulation Group II, Black, Sealable |
|---|
| Recommended Screw Driver | Pozidriv 2 |
|---|
| Accessories Available | Yes |
|---|
| Connecting Capacity | {
"Busbar_Attribute": "10/10 mm²",
"Flexible_with_Ferrule_Attribute": "0.75 … 25 mm²",
"Flexible_Attribute": "0.75 … 25 mm²",
"Rigid_Attribute": "0.75 … 35 mm²",
"Stranded_Attribute": "0.75 … 35 mm²"
} |
|---|
| Busbar | 18-8 AWG |
|---|
| Flexible with Ferrule | 0.75 … 25 mm² |
|---|
| Flexible | 0.75 … 25 mm² |
|---|
| Rigid | 0.75 … 35 mm² |
|---|
| Stranded | 0.75 … 35 mm² |
|---|
| Installation Size | acc. to DIN 43880 1 |
|---|
| Wire Stripping Length mm | 1.25 |
|---|
| Terminal Type | Screw Terminals |
|---|
| Electrical | {
"Tripping_Characteristic_Attribute": "C",
"Rated_Operational_Voltage_Attribute": "acc. to IEC 60898-1 230/400 V AC and acc. to IEC 60947-2 230 V AC",
"Operational_Voltage_Attribute": {
"Maximum_Incl_Tolerance_V_AC_Attribute": 253,
"Maximum_Incl_Tolerance_V_DC_Attribute": 72,
"Minimum_V_AC_Attribute": 12,
"Minimum_V_DC_Attribute": 12
},
"Rated_Insulation_Voltage_Ui_Attribute": 440,
"Rated_Impulse_Withstand_Voltage_Uimp_kV_Attribute": 4,
"Input_Voltage_Type_Attribute": "AC/DC",
"Rated_Current_A_Attribute": 32,
"Rated_Short-Circuit_Capacity_AC_kA_Attribute": 6,
"Rated_Short-Circuit_Capacity_DC_kA_Attribute": 6,
"Rated_Conditional_Short-Circuit_Current_Inc_Attribute": {
"230_V_Attribute": 10,
"400_V_Attribute": 10
},
"Frequency_Hz_Attribute": 50,
"Rated_Frequency_Hz_Attribute": "50 / 60",
"Power_Loss_W_Attribute": 3.7,
"Overvoltage_Category_Attribute": "III"
} |
|---|
| Tripping Characteristic | C |
|---|
| Rated Operational Voltage | acc. to IEC 60898-1 230/400 V AC and acc. to IEC 60947-2 230 V AC |
|---|
| Operational Voltage | {
"Maximum_Incl_Tolerance_V_AC_Attribute": 253,
"Maximum_Incl_Tolerance_V_DC_Attribute": 72,
"Minimum_V_AC_Attribute": 12,
"Minimum_V_DC_Attribute": 12
} |
|---|
| Maximum Incl Tolerance V AC | 253 |
|---|
| Maximum Incl Tolerance V DC | 72 |
|---|
| Minimum V AC | 12 |
|---|
| Minimum V DC | 12 |
|---|
| Rated Insulation Voltage Ui | 440 |
|---|
| Rated Impulse Withstand Voltage Uimp kV | 4 |
|---|
| Input Voltage Type | AC/DC |
|---|
| Rated Current A | 32 |
|---|
| Rated Short-Circuit Capacity AC kA | 6 |
|---|
| Rated Short-Circuit Capacity DC kA | 6 |
|---|
| Rated Conditional Short-Circuit Current Inc | {
"230_V_Attribute": 10,
"400_V_Attribute": 10
} |
|---|
| Frequency Hz | 50 |
|---|
| Rated Frequency Hz | 50 / 60 |
|---|
| Power Loss W | 3.7 |
|---|
| Overvoltage Category | III |
|---|
| Design | {
"Housing_Material_Attribute": "Insulation Group II, RAL 7035"
} |
|---|
| Housing Material | Insulation Group II, RAL 7035 |
|---|
| Technical UL CSA | {
"Maximum_Operating_Voltage_Attribute": {
"UL_CSA_60_V_DC_Attribute": 60,
"UL_CSA_480Y_277_V_AC_Attribute": "480Y/277 V AC"
},
"Interrupting_Rating_acc_to_UL1077_Attribute": {
"277_V_AC_kA_Attribute": 6,
"60_V_DC_kA_Attribute": 10,
"120_V_kA_Attribute": 10
},
"Connecting_Capacity_UL_CSA_Attribute": {
"Busbar_Attribute": "18-8 AWG",
"Conductor_Attribute": "18-4 AWG"
},
"Tightening_Torque_UL_CSA_in_lb_Attribute": 18
} |
|---|
| Maximum Operating Voltage | {
"UL_CSA_60_V_DC_Attribute": 60,
"UL_CSA_480Y_277_V_AC_Attribute": "480Y/277 V AC"
} |
|---|
| UL CSA 60 V DC | 60 |
|---|
| UL CSA 480Y 277 V AC | 480Y/277 V AC |
|---|
| Interrupting Rating acc to UL1077 | {
"277_V_AC_kA_Attribute": 6,
"60_V_DC_kA_Attribute": 10,
"120_V_kA_Attribute": 10
} |
|---|
| 277 V AC kA | 6 |
|---|
| 60 V DC kA | 10 |
|---|
| 120 V kA | 10 |
|---|
| Connecting Capacity UL CSA | {
"Busbar_Attribute": "18-8 AWG",
"Conductor_Attribute": "18-4 AWG"
} |
|---|
| Conductor | 18-4 AWG |
|---|
| Tightening Torque UL CSA in lb | 18 |
|---|
| Material Compliance | {
"RoHS_Declaration_Attribute": "Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019",
"RoHS_Date_Attribute": "20240228",
"REACH_Declaration_Attribute": "False – does not contain substances > 0.1 mass percentage",
"REACH_Date_Attribute": "20250917",
"Conflict_Minerals_Reporting_Template_Attribute": "Available",
"SCIP_Attribute": "e6800e55-46b1-49a3-881b-0f66d0e903ad Germany",
"WEEE_Category_Attribute": "5. Small Equipment (No External Dimension More Than 50 cm)",
"WEEE_B2C_B2B_Attribute": "Business To Business"
} |
|---|
| RoHS Declaration | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|
| RoHS Date | 20240228 |
|---|
| REACH Declaration | False – does not contain substances > 0.1 mass percentage |
|---|
| REACH Date | 20250917 |
|---|
| Conflict Minerals Reporting Template | Available |
|---|
| SCIP | e6800e55-46b1-49a3-881b-0f66d0e903ad Germany |
|---|
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
|---|
| WEEE B2C B2B | Business To Business |
|---|
| Environmental | {
"Ambient_Air_Temperature_Operation_C_Attribute": "-25 … +55",
"Ambient_Air_Temperature_Storage_C_Attribute": "-40 … +70",
"Reference_Ambient_Air_Temperature_C_Attribute": 30,
"Degree_of_Protection_Attribute": "IP20, IP40 Enclosure with Cover IP40",
"Pollution_Degree_Attribute": 3,
"Environmental_Conditions_Attribute": "28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %",
"Resistance_to_Vibrations_Attribute": "20 Cycles with Load 0.8 In: 5g 5 … 150 … 5 Hz",
"Resistance_to_Shock_acc_to_IEC_60068-2-27_Attribute": "25g 2 shocks 13 ms"
} |
|---|
| Ambient Air Temperature Operation C | -25 … +55 |
|---|
| Ambient Air Temperature Storage C | -40 … +70 |
|---|
| Reference Ambient Air Temperature C | 30 |
|---|
| Degree of Protection | IP20, IP40 Enclosure with Cover IP40 |
|---|
| Pollution Degree | 3 |
|---|
| Environmental Conditions | 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % |
|---|
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 5g 5 … 150 … 5 Hz |
|---|
| Resistance to Shock acc to IEC 60068-2-27 | 25g 2 shocks 13 ms |
|---|
| Dimensions | {
"Width_in_Number_of_Modular_Spacings_Attribute": 1,
"Pole_Net_Weight_kg_Attribute": 0.125,
"Built-In_Depth_t2_cm_Attribute": 6.9
} |
|---|
| Width in Number of Modular Spacings | 1 |
|---|
| Pole Net Weight kg | 0.125 |
|---|
| Built-In Depth t2 cm | 6.9 |
|---|
| Engineering | {
"EPLAN_Data_Attribute": "Available"
} |
|---|
| EPLAN Data | Available |
|---|
| Ordering | {
"Package_Level_1_Units_Attribute": "carton 10 piece",
"Package_Level_1_Gross_Weight_kg_Attribute": 1.24,
"E-Number_Finland_Attribute": "3210432",
"E-Number_Norway_Attribute": "1664841",
"E-Number_Sweden_Attribute": "2100526"
} |
|---|
| Package Level 1 Units | carton 10 piece |
|---|
| Package Level 1 Gross Weight kg | 1.24 |
|---|
| E-Number Finland | 3210432 |
|---|
| E-Number Norway | 1664841 |
|---|
| E-Number Sweden | 2100526 |
|---|
| Certificates and Declarations | {
"Declaration_of_Conformity_CE_Attribute": "Available",
"Declaration_of_Conformity_UKCA_Attribute": "Available"
} |
|---|
| Declaration of Conformity CE | Available |
|---|
| Declaration of Conformity UKCA | Available |
|---|
| Installation | {
"Instructions_and_Manuals_Attribute": "Available",
"Mounting_Type_Attribute": "DIN-Rail",
"Mounting_on_DIN_Rail_Attribute": [
"TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715",
"TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715"
],
"Mounting_Position_Attribute": "any"
} |
|---|
| Instructions and Manuals | Available |
|---|
| Mounting Type | DIN-Rail |
|---|
| Mounting on DIN Rail | [
"TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715",
"TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715"
] |
|---|
| Mounting Position | any |
|---|
| Customs Tariff Code | 39121603 |
|---|