Block Contactor UA110-30-00RA-80
A 3-phase Contactor suitable for Capacitor switching application. Maximum permissible peak current 100 times the nominal RMS current. Operated with a control voltage, versions from 24…690 V.
Product ID: 1SFL451024R8000
EAN: 7320500260524
Minimum Order Quantity: 1 piece
Customs Tariff Number: 85364900
Dimensions (cm): Width: 9, Depth/Length: 15.56, Height: 17
Weight (kg): 1.8
Electrical Specifications:
Number of Main Contacts NO: 3
Number of Main Contacts NC: 0
Number of Auxiliary Contacts NO: 0
Number of Auxiliary Contacts NC: 0
Number of Poles: 3P
Rated Operational Voltage: Main Circuit 1000 V
Rated Frequency: Main Circuit 50 Hz
Conventional Free-air Thermal Current Ith: 160 A
Rated Operational Current AC-1 (Ie): 690 V 40 °C 160 A, 690 V 55 °C 145 A, 690 V 60 °C 145 A, 690 V 70 °C 130 A
Rated Operational Current AC-3 (Ie): 415 V 55 °C 110 A, 440 V 55 °C 100 A, 500 V 55 °C 100 A, 690 V 55 °C 82 A, 1000 V 55 °C 30 A, 380/400 V 55 °C 110 A, 220/230/240 V 55 °C 110 A
Rated Operational Power AC-6b (Pe): varies from 35 kvar to 130 kvar depending on voltage and temperature
Rated Breaking Capacity AC-3: 8 x Ie AC-3
Rated Making Capacity AC-3: 10 x Ie AC-3
Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A, at 690 V 800 A
Rated Insulation Voltage (Ui): 1000 V (IEC 60947-4-1 and VDE 0110 Gr. C), 600 V (UL/CSA)
Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Maximum Electrical Switching Frequency: AC-1 300 cycles/hr, AC-2/AC-4 150 cycles/hr, AC-3 300 cycles/hr
Mechanical Durability: 10 million cycles
Maximum Mechanical Switching Frequency: 3600 cycles/hr
Coil and Control Details:
Coil Operating Limits: 0.85 x Uc Min. to 1.1 x Uc Max. at <= 70 °C
Rated Control Circuit Voltage (Uc): 50 Hz 220-230 V, 60 Hz 230-240 V
Coil Consumption: Holding 22 V·A (50 Hz), 26 V·A (60 Hz); Pull-in 350 V·A (50 Hz), 450 V·A (60 Hz)
Power Loss: 7.5 W per pole
Operation Times:
Between Coil De-energization and NC Contact Closing: 7 to 15 ms
Between Coil Energization and NO Contact Closing: 10 to 25 ms
Connection Capacities:
Main Circuit: Bar 30 mm², Flexible with Cable End 1 x 10 to 70 mm², Rigid 2 x 6 to 65 mm²
Auxiliary Circuit: Flexible with Ferrule 2x 0.75 to 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 to 2.5 mm², Flexible 2×0.75 to 2.5 mm², Solid 2 x 1 to 4 mm², Stranded 1 x 1 to 4 mm²
Connecting Capacity: Bar 30 mm², Flexible with Cable End 2 x 6 to 35 mm², Rigid 1 x 10 to 95 mm²
Protection and Terminals:
Degree of Protection: Coil Terminals IP20, Main Terminals IP10 as per IEC 60529, IEC 60947-1, EN 60529
Connecting Terminals Main Poles: M8 hexagon socket screw with single connector
Tightening Torque Main Circuit: 8 N·m
Terminal Type: Cable Clamp
UL/CSA Maximum Operating Voltage: Main Circuit 600 V
Environmental and Mechanical:
Ambient Air Temperature Close to Contactor with Thermal OL Relay: -25 to 50 °C
Without Thermal OL Relay: -40 to 70 °C
For Storage: -60 to +80 °C
Maximum Operating Altitude Permissible Without Derating: 3000 m
Shock Resistance acc. to IEC 60068-2-27: Half-sine pulse 11 ms, various directions 5g to 20g, no change in contact position
Packaging:
Box with 1 piece
Dimensions (cm): Width 17, Depth/Length 14, Height 17
Gross Weight: 2 kg